Share:

BEDFORD PARK BLVD over METRO NO COMMUTER

Map

Coordinates:
+40.86662, -73.88310
40°51'60" N, 73°52'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BEDFORD PARK BLVD over METRO NO COMMUTER
Structure number:000000002241840
Location:IN FORDHAM
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:57.7 ft. [17.6 m]
Total length:65.0 ft. [19.8 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:100.1 ft. [30.5 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:City or Municipal Highway Agency [04]
Year built:1889
Year reconstructed:1936
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:20,160 [as of 2016]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:72.7
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$960,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2016FairFairSatisfactorySatisfactory2016072.7
April 2014FairFairSatisfactorySatisfactory1585873.0
April 2012FairFairSatisfactorySatisfactory1585873.0
May 2010FairFairSatisfactorySatisfactory1585873.0
April 2008PoorPoorSatisfactorySatisfactory887471.4
April 2006FairFairSatisfactorySatisfactory1585860.5
April 2004FairFairSatisfactorySatisfactory1585860.5
March 2002FairFairSatisfactorySatisfactory1585873.0
March 2000PoorPoorFairSatisfactory1585863.8
November 1998PoorPoorFairSatisfactory1585863.8
May 1996PoorPoorPoorFair2234163.7
August 1994PoorPoorPoorFair1600033.6
August 1992PoorPoorPoorFair1600033.6
August 1990PoorPoorPoorFair1600033.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,2761,17610000
Steel Protective Coatingsq. ft.2,3122,11220000
Deck
Reinforced Concrete Decksq. ft.6,0001,20004,8000
Wearing Surfacessq. ft.3,6003,36002400
Substructure
Masonry Abutmentlinear ft.200200000
Joints
Pourable Jointlinear ft.200002000
Bearings
Movable Bearingeach2200220
Steel Protective Coatingsq. ft.8375008
Fixed Bearingeach2200220
Steel Protective Coatingsq. ft.8375008
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.120120000
Steel Protective Coatingsq. ft.480480000