Share:

EAST 14TH STREET over N Y & ATLANTIC/LI

Map

Coordinates:
+40.62894, -73.96304
40°37'44" N, 73°57'47" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:EAST 14TH STREET over N Y & ATLANTIC/LI
Structure number:000000002243450
Location:AT KENSINGSTON
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Local (Urban) [19]
Length of largest span:31.8 ft. [9.7 m]
Total length:35.1 ft. [10.7 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:50.9 ft. [15.5 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1908
Year reconstructed:1982
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,533 [as of 2010]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:89.1
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$257,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016FairSatisfactorySatisfactorySatisfactory253389.1
September 2014FairSatisfactorySatisfactorySatisfactory253389.1
September 2012FairSatisfactorySatisfactorySatisfactory255089.1
December 2010FairSatisfactorySatisfactorySatisfactory338577.8
December 2008FairSatisfactorySatisfactorySatisfactory338577.8
October 2006FairSatisfactorySatisfactorySatisfactory209589.1
November 2004GoodGoodVery GoodVery Good209589.1
July 2002GoodGoodVery GoodVery Good209589.1
March 2000GoodGoodGoodGood209593.1
January 1998Fair-GoodSatisfactory209593.1
March 1996Fair-SatisfactoryFair230282.0
May 1994Fair-SatisfactoryFair240082.0
March 1992Fair-SatisfactoryFair240082.0
May 1990Fair-SatisfactoryFair240082.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.352035200
Deck
Prestressed Concrete Top Flangesq. ft.1,80501,80500
Wearing Surfacessq. ft.1,05501,05500
Substructure
Reinforced Concrete Abutmentlinear ft.10209750
Bearings
Elastomeric Bearingeach2202200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.7007000