Share:

WEST 41ST STREET over AMTRAK W SIDE CON

Map

Coordinates:
+40.75934, -73.99687
40°45'34" N, 73°59'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WEST 41ST STREET over AMTRAK W SIDE CON
Structure number:000000002245330
Location:IN MANHATTAN
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:37.7 ft. [11.5 m]
Total length:104.0 ft. [31.7 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:10°
Owner:City or Municipal Highway Agency [04]
Year built:1935
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,902 [as of 2015]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:62.6
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$15,744,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016FairFairSatisfactoryFair490262.6
July 2014FairFairSatisfactoryFair356062.7
June 2012FairFairSatisfactoryFair356062.7
September 2010FairFairSatisfactoryFair399762.7
December 2008FairFairSatisfactoryFair409262.7
September 2006FairFairSatisfactoryFair356062.7
September 2004FairFairSatisfactoryFair356062.7
July 2002FairFairSatisfactoryFair363162.7
April 2000FairFairSatisfactoryFair363166.7
February 1998FairFairSatisfactoryFair363166.7
April 1996PoorPoorPoorPoor2039834.6
April 1994PoorPoorPoorPoor2240035.3
February 1992PoorPoorPoorPoor2240040.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,20501,166390
Steel Protective Coatingsq. ft.1,4460105499842
Deck
Reinforced Concrete Decksq. ft.6,28206,1611210
Wearing Surfacessq. ft.3,97603,97600
Substructure
Steel Columneach80800
Reinforced Concrete Pier Walllinear ft.98049490
Reinforced Concrete Abutmentlinear ft.126012330
Steel Pier Caplinear ft.126012600
Steel Protective Coatingsq. ft.1,62801,62800
Bearings
Fixed Bearingeach2402400
Steel Protective Coatingsq. ft.2402400
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.50500