Share:

RIVERSIDE DRIVE over WEST 158TH STREET, AMTRA

Map

Coordinates:
+40.83644, -73.94852
40°50'11" N, 73°56'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RIVERSIDE DRIVE over WEST 158TH STREET, AMTRA
Structure number:000000002246720
Location:IN NW MANHATTAN
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:68.9 ft. [21.0 m]
Total length:1925.9 ft. [587.0 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:97.1 ft. [29.6 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:22°
Owner:City or Municipal Highway Agency [04]
Year built:1927
Year reconstructed:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:39
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:56.8
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$133,609,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017FairFairFairFair-56.8
November 2016FairFairFairFair-61.1
October 2015FairFairFairFair1742938.6
October 2014FairFairFairFair1742938.9
October 2013FairFairFairFair1742938.9
December 2011FairFairFairFair1742938.9
September 2010PoorFairPoorFair1742923.0
September 2009FairFairFairFair1742938.9
November 2007FairFairSatisfactoryFair1742938.9
November 2005FairFairSatisfactoryFair1742938.9
November 2003FairFairSatisfactoryFair1742975.9
August 2001FairFairSatisfactoryFair1673438.7
November 1999FairFairSatisfactoryFair1673438.7
August 1997PoorFairPoorPoor1627925.3
May 1995PoorPoorPoorPoor1627923.1
March 1994PoorPoorPoorSerious1660022.9
March 1993PoorPoorSeriousPoor1660022.9
February 1992PoorPoorSeriousPoor1660021.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.37,97537,2202025530
Steel Protective Coatingsq. ft.250,328227,7195,680016,929
Steel Stringerlinear ft.1,8951,558123250
Steel Protective Coatingsq. ft.13,01712,426620529
Deck
Reinforced Concrete Decksq. ft.117,6532,73888,82526,0900
Wearing Surfacessq. ft.110,92644,03924,08042,8070
Superstructure
Steel Floor Beamlinear ft.5,5245,41076380
Steel Protective Coatingsq. ft.28,57627,84800728
Substructure
Steel Columneach15112310180
Steel Protective Coatingsq. ft.63,06256,4693,7311,3191,543
Other Material Columneach10010
Reinforced Concrete Pier Walllinear ft.63229803340
Masonry Pier Walllinear ft.9212602494120
Reinforced Concrete Abutmentlinear ft.97023740
Masonry Abutmentlinear ft.1501500
Reinforced Concrete Pile Cap/Footinglinear ft.545545000
Steel Pier Caplinear ft.6,5265,6862415990
Steel Protective Coatingsq. ft.129,622120,9153,4896704,548
Joints
Compression Jointlinear ft.2,4291651,0841,1800
Bearings
Movable Bearingeach468207592020
Steel Protective Coatingsq. ft.1,095740440311
Fixed Bearingeach907675201310
Steel Protective Coatingsq. ft.1,19577922082114
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.666666000
Other Material Bridge Raillinear ft.2,8982,898000