Share:

GARAGE RAMP TO 79 over SB HHP RAMP TO 79, 79ST

Map

Coordinates:
+40.78610, -73.98460
40°47'10" N, 73°59'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:GARAGE RAMP TO 79 over SB HHP RAMP TO 79, 79ST
Structure number:00000000226771C
Location:79 ST BOAT BASIN
Purpose:Carries highway over highway
Route classification:Local (Urban) [19]
Length of largest span:27.9 ft. [8.5 m]
Total length:426.9 ft. [130.1 m]
Roadway width between curbs:18.0 ft. [5.5 m]
Deck width edge-to-edge:23.0 ft. [7.0 m]
Vertical clearance above deck:8.5 ft. [2.6 m]
Vertical clearance below bridge:6.6 ft. [2.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1935
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:21
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:300 [as of 2009]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:59.5
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$6,131,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairSatisfactorySatisfactorySatisfactory30059.5
May 2016FairFairSatisfactorySatisfactory30058.5
May 2015FairFairSatisfactorySatisfactory30079.8
May 2014FairFairSatisfactorySatisfactory30083.2
May 2013FairFairSatisfactorySatisfactory30078.5
May 2012FairFairSatisfactorySatisfactory30077.2
May 2011FairFairSatisfactorySatisfactory30077.2
May 2009FairFairSatisfactorySatisfactory30049.2
July 2007FairFairSatisfactorySatisfactory30083.7
June 2005FairSatisfactorySatisfactorySatisfactory30084.7
June 2003FairSatisfactorySatisfactorySatisfactory30083.2
October 2001FairFairSatisfactorySatisfactory30081.8
December 1999FairFairFairFair30067.7
October 1997PoorFairFairPoor30051.7
September 1995PoorPoorPoorPoor30058.0
October 1993PoorPoorPoorPoor30051.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,6632,58459200
Steel Protective Coatingsq. ft.14,64312,8611,7045226
Steel Stringerlinear ft.115115000
Steel Protective Coatingsq. ft.490490000
Deck
Reinforced Concrete Decksq. ft.11,8289,2702,539190
Wearing Surfacessq. ft.6,5373,5692142,7540
Superstructure
Steel Floor Beamlinear ft.6767000
Steel Protective Coatingsq. ft.2902702000
Substructure
Steel Columneach2921440
Steel Protective Coatingsq. ft.4,6724,2033276280
Reinforced Concrete Pier Walllinear ft.3723541800
Reinforced Concrete Abutmentlinear ft.2121000
Steel Pier Caplinear ft.9448796500
Steel Protective Coatingsq. ft.8,4087,3479696428
Bearings
Enclosed/Concealed Bearingeach1818000
Steel Protective Coatingsq. ft.6868000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1251051190
Masonry Bridge Raillinear ft.128087410