COLLEGE AVENUE over CASCADILLA CREEK

Map

Coordinates:
+42.44334, -76.48529
42°26'36" N, 76°29'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COLLEGE AVENUE over CASCADILLA CREEK
Structure number:000000002268290
Location:300FT N INT COLLEGE & OAK
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:63.0 ft. [19.2 m]
Total length:86.0 ft. [26.2 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:40.4 ft. [12.3 m]
Owner:Private (other than railroad) [26]
Year built:1953
Year reconstructed:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Arch - Deck [11]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:71.1
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$2,226,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017Fair-FairGood-71.1
September 2015Good-GoodGood825477.5
November 2013Good-GoodGood825477.5
November 2011Good-GoodGood825477.5
November 2009Good-GoodGood825477.5
August 2007Good-GoodGood825477.5
October 2005Good-GoodGood825477.5
September 2003Good-GoodGood825477.5
July 2001Fair-SatisfactorySatisfactory825477.5
June 1999Fair-SatisfactorySatisfactory704277.6
July 1997Fair-SatisfactorySatisfactory600077.6
October 1995Fair-FairFair600066.3
September 1993Fair-Fair-600066.3
November 1991Fair-Satisfactory-600077.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Archlinear ft.7300730
Bridge Rail
Masonry Bridge Raillinear ft.146146000