STICKNEY BR ROAD over E B AUSABLE RIVER
Map
Coordinates:
+44.41295, -73.6809444°24'47" N, 73°40'51" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | STICKNEY BR ROAD over E B AUSABLE RIVER |
Structure number: | 000000003302070 |
Location: | 2 MI S OF AU SABLE FORKS |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 114.8 ft. [35.0 m] |
Total length: | 117.1 ft. [35.7 m] |
Roadway width between curbs: | 15.7 ft. [4.8 m] |
Deck width edge-to-edge: | 17.1 ft. [5.2 m] |
Owner: | County Highway Agency [02] |
Year built: | 1928 |
Year reconstructed: | 2013 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Corrugated Steel [6] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 318 [as of 2014] |
Truck traffic: | 8% of total traffic |
Deck condition: | Excellent [9 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 71.1 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $2,517,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Excellent | Very Good | Fair | 318 | 71.1 |
May 2016 | Fair | Excellent | Very Good | Fair | 319 | 66.2 |
June 2014 | Fair | Excellent | Very Good | Fair | 164 | 64.3 |
June 2013 | Poor | Fair | Poor | Fair | 164 | 25.8 |
August 2011 | Fair | Fair | Satisfactory | Fair | 160 | 68.2 |
September 2009 | Fair | Fair | Good | Fair | 494 | 68.0 |
July 2007 | Fair | Fair | Good | Fair | 532 | 68.0 |
June 2005 | Fair | Fair | Good | Fair | 516 | 68.0 |
August 2003 | Fair | Fair | Good | Fair | 516 | 68.0 |
October 2001 | Poor | Poor | Good | Fair | 516 | 67.0 |
September 1999 | Fair | Fair | Good | Satisfactory | 50 | 84.2 |
September 1997 | Poor | Poor | Satisfactory | Poor | 50 | 55.2 |
September 1995 | Poor | Very Good | Very Good | Poor | 50 | 52.8 |
September 1994 | Poor | Serious | Serious | Poor | 50 | 25.6 |
August 1993 | Poor | Serious | Serious | Poor | 50 | 31.0 |
July 1992 | Poor | Serious | Serious | Poor | 50 | 31.0 |
August 1991 | Poor | Serious | - | Poor | 50 | 27.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 570 | 570 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,059 | 2,059 | 0 | 0 | 0 |
Steel Truss | linear ft. | 230 | 230 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 4,582 | 4,582 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 160 | 160 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 977 | 977 | 0 | 0 | 0 |
Steel Gusset Plate | each | 48 | 48 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 384 | 384 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 141 | 0 | 74 | 67 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 56 | 0 | 17 | 39 | 0 |
Deck |
Corrugated or Orthotropic Deck | sq. ft. | 1,843 | 1,843 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,832 | 0 | 1,832 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 32 | 0 | 32 | 0 | 0 |
Bearings |
Movable Bearing | each | 7 | 0 | 7 | 0 | 0 |
Steel Protective Coating | sq. ft. | 14 | 0 | 14 | 0 | 0 |
Fixed Bearing | each | 7 | 0 | 7 | 0 | 0 |
Steel Protective Coating | sq. ft. | 14 | 0 | 14 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 230 | 230 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 460 | 0 | 460 | 0 | 0 |