MAIN STREET over ERIE CANAL
Map
Coordinates:
+43.16928, -78.6950443°10'09" N, 78°41'42" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | MAIN STREET over ERIE CANAL |
Structure number: | 000000004454170 |
Location: | AT JCT RTS 78 + 31 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 130.9 ft. [39.9 m] |
Total length: | 131.9 ft. [40.2 m] |
Roadway width between curbs: | 56.1 ft. [17.1 m] |
Deck width edge-to-edge: | 399.3 ft. [121.7 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1912 |
Year reconstructed: | 1992 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Other [00] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 11,458 [as of 2018] |
Truck traffic: | 2% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | In place but in a deteriorated condition [3] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 94.4 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $35,565,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 11458 | 94.4 |
September 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 7889 | 94.6 |
September 2015 | Poor | Good | Poor | Satisfactory | 8824 | 66.7 |
September 2014 | Poor | Good | Poor | Satisfactory | 10939 | 66.4 |
October 2013 | Poor | Good | Poor | Satisfactory | 11442 | 66.4 |
October 2011 | Good | Good | Good | Good | 10700 | 95.5 |
October 2009 | Good | Good | Good | Good | 10960 | 95.5 |
October 2007 | Good | Good | Good | Good | 10925 | 92.5 |
October 2005 | Good | Good | Good | Good | 10960 | 95.5 |
October 2003 | Good | Good | Good | Good | 10960 | 95.5 |
October 2001 | Good | Very Good | Good | Good | 10960 | 96.5 |
October 1999 | Good | Very Good | Good | Good | 10960 | 94.5 |
October 1997 | Poor | Satisfactory | Satisfactory | Poor | 11196 | 67.2 |
November 1995 | Poor | Fair | Fair | Poor | 10469 | 64.8 |
November 1994 | Poor | Fair | Fair | Poor | 1000 | 65.9 |
November 1993 | Poor | Fair | Fair | Poor | 14197 | 47.1 |
October 1991 | Poor | Fair | Fair | Poor | 14197 | 65.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 1,836 | 0 | 1,836 | 0 | 0 |
Steel Protective Coating | sq. ft. | 3,971 | 0 | 3,971 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 52,405 | 36,683 | 7,861 | 7,861 | 0 |
Wearing Surfaces | sq. ft. | 45,098 | 40,588 | 4,284 | 226 | 0 |
Superstructure |
Steel Arch | linear ft. | 4,281 | 3,553 | 471 | 257 | 0 |
Steel Protective Coating | sq. ft. | 235,440 | 211,900 | 23,540 | 0 | 0 |
Steel Floor Beam | linear ft. | 19,025 | 16,932 | 2,079 | 14 | 0 |
Steel Protective Coating | sq. ft. | 72,513 | 58,010 | 9,427 | 5,076 | 0 |
Steel Pin or Pin & Hangar Assembly | each | 36 | 26 | 10 | 0 | 0 |
Steel Protective Coating | sq. ft. | 360 | 270 | 0 | 90 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 804 | 438 | 225 | 141 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 403 | 323 | 44 | 36 | 0 |
Joints |
Compression Joint | linear ft. | 1,640 | 410 | 410 | 820 | 0 |
Bearings |
Fixed Bearing | each | 72 | 0 | 24 | 48 | 0 |
Steel Protective Coating | sq. ft. | 2,016 | 684 | 666 | 666 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 262 | 262 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,661 | 1,661 | 0 | 0 | 0 |