Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WEST 39TH STREET over DYER AVENUE
Structure number:000000005522380
Location:IN WEST MANHATTAN
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Collector (Urban) [17]
Length of largest span:128.0 ft. [39.0 m]
Total length:129.9 ft. [39.6 m]
Roadway width between curbs:36.1 ft. [11.0 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:Local Toll Authority [32]
Year built:1936
Year reconstructed:1971
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,129 [as of 2011]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:75.1
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$7,757,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017FairSatisfactorySatisfactorySatisfactory712975.1
July 2015FairSatisfactorySatisfactorySatisfactory652875.6
July 2013FairSatisfactorySatisfactorySatisfactory652875.6
July 2011FairFairSatisfactorySatisfactory652874.6
July 2009FairFairSatisfactoryFair652863.5
November 2007FairFairSatisfactoryFair652863.5
August 2005FairFairSatisfactoryFair652863.5
October 2003FairSatisfactorySatisfactorySatisfactory652875.6
October 2001FairSatisfactorySatisfactorySatisfactory507075.7
September 1999FairSatisfactorySatisfactorySatisfactory507075.7
July 1997FairSatisfactorySatisfactoryFair320064.8
September 1995PoorFairFairPoor320048.4
October 1993PoorSatisfactoryFairPoor870048.4
September 1991FairSatisfactorySatisfactoryFair320064.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.235232300
Steel Protective Coatingsq. ft.5,3504,54880200
Steel Stringerlinear ft.850846130
Steel Protective Coatingsq. ft.6,5505,57497060
Deck
Reinforced Concrete Decksq. ft.7,0376,92311400
Wearing Surfacessq. ft.6,8006,800000
Superstructure
Steel Floor Beamlinear ft.390390000
Steel Protective Coatingsq. ft.5,2654,47579000
Joints
Compression Jointlinear ft.138013440
Bearings
Movable Bearingeach134090
Steel Protective Coatingsq. ft.6565000
Fixed Bearingeach1313000
Steel Protective Coatingsq. ft.6565000