Share:

RTE I95 over RTE 9A, HUDSON RIVER

Map

Coordinates:
+40.85175, -73.95199
40°51'06" N, 73°57'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE I95 over RTE 9A, HUDSON RIVER
Structure number:000000005522507
Location:95I OVER HUDSON RIVER LL
Purpose:Carries highway over highway and waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Tolls:Yes [1]
Length of largest span:3500.2 ft. [1066.8 m]
Total length:4986.1 ft. [1519.7 m]
Roadway width between curbs:71.9 ft. [21.9 m]
Deck width edge-to-edge:104.0 ft. [31.7 m]
Vertical clearance above deck:14.4 ft. [4.4 m]
Vertical clearance below bridge:210.0 ft. [64.0 m]
Owner:Local Toll Authority [32]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Suspension [13]
Deck type:Closed Grating [4]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:268,692 [as of 2014]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:52.3
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$778,599,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2017FairSatisfactoryFairFair26869252.3
September 2015FairSatisfactoryFairFair26869252.3
September 2013FairSatisfactoryFairFair29770052.2
September 2011FairSatisfactorySatisfactorySatisfactory29770063.2
October 2009FairSatisfactorySatisfactorySatisfactory28562063.2
December 2007FairSatisfactorySatisfactorySatisfactory29734263.2
September 2005FairSatisfactorySatisfactorySatisfactory29770063.2
September 2003FairGoodSatisfactoryGood29770062.2
November 2001FairGoodSatisfactoryGood29770066.0
August 1999FairGoodSatisfactoryGood21600068.0
October 1997FairSatisfactorySatisfactoryFair15188457.0
August 1995PoorFairPoorPoor15188446.0
August 1993FairFairFairFair15000057.0
June 1991FairSatisfactoryFairFair16888247.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.3,4081,7901,579390
Steel Protective Coatingsq. ft.20,737018,00102,736
Steel Stringerlinear ft.83,634071,55212,0820
Steel Protective Coatingsq. ft.850,5490111,642301,555437,352
Deck
Reinforced Concrete Decksq. ft.12,6909,3073,38300
Wearing Surfacessq. ft.12,69012,690000
Superstructure
Steel Trusslinear ft.9,124009,1240
Steel Protective Coatingsq. ft.1,040,1110526,349513,7620
Steel Floor Beamlinear ft.19,56106,23213,3290
Steel Protective Coatingsq. ft.349,49500150,838198,657
Steel Gusset Plateeach31201661460
Steel Protective Coatingsq. ft.6,2004,2501,95000
Substructure
Steel Columneach60600
Steel Protective Coatingsq. ft.2,24402,24400
Other Material Abutmentlinear ft.106010600
Steel Pier Caplinear ft.308030800
Steel Protective Coatingsq. ft.7,0541,7654,9260363
Deck
Concrete Filled Grid Decksq. ft.343,4172,867276,58263,9680
Wearing Surfacessq. ft.343,417343,417000
Joints
Compression Jointlinear ft.2160721440
Assembly without Seal Jointlinear ft.4320384480
Bearings
Movable Bearingeach3301320
Steel Protective Coatingsq. ft.6602064
Fixed Bearingeach126012510
Steel Protective Coatingsq. ft.32401440180
Other Bearingeach299029900
Steel Protective Coatingsq. ft.598059800
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.18,3280018,3244
Steel Protective Coatingsq. ft.18,318010,18508,133
Reinforced Concrete Bridge Raillinear ft.652652000