Share:

RAMP 179 over HENRY HUD PKWY NB, RAMP

Map

Coordinates:
+40.84976, -73.94222
40°50'59" N, 73°56'32" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP 179 over HENRY HUD PKWY NB, RAMP
Structure number:00000000552250C
Location:95I OVER HUDSON RIVER
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:68.9 ft. [21.0 m]
Total length:1250.1 ft. [381.0 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:42.7 ft. [13.0 m]
Vertical clearance above deck:17.4 ft. [5.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:Local Toll Authority [32]
Year built:1931
Year reconstructed:1962
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:50
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: September 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:60.6
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$33,541,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2017FairFairFairFair-60.6
September 2015FairFairFairFair-68.4
September 2013FairSatisfactorySatisfactoryFair963353.5
September 2011FairSatisfactorySatisfactoryFair963355.5
August 2009FairSatisfactorySatisfactorySatisfactory963365.6
August 2007FairSatisfactorySatisfactorySatisfactory96335.2
July 2005FairSatisfactorySatisfactorySatisfactory96335.2
September 2003FairSatisfactorySatisfactoryFair963354.5
September 2001FairSatisfactorySatisfactoryFair963350.1
September 1999FairSatisfactorySatisfactoryFair963348.1
September 1997PoorFairPoorFair16716321.1
October 1995PoorPoorPoorPoor16716319.0
September 1993PoorFairPoorPoor16716317.4
August 1991PoorFairFairPoor16716329.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.21210111010
Steel Protective Coatingsq. ft.3,1801,2901,5853005
Steel Stringerlinear ft.5,2713,7441,509180
Steel Protective Coatingsq. ft.52,71025,04125,2902,36712
Deck
Reinforced Concrete Decksq. ft.40,76031,7678,8231700
Wearing Surfacessq. ft.29,787029,700870
Superstructure
Steel Floor Beamlinear ft.27611016600
Steel Protective Coatingsq. ft.3,5881,4352,15300
Substructure
Steel Columneach66024420
Steel Protective Coatingsq. ft.9,9004,5644,90641911
Reinforced Concrete Columneach1901720
Reinforced Concrete Pier Walllinear ft.64046180
Reinforced Concrete Abutmentlinear ft.4704520
Steel Pier Caplinear ft.1,1404971255180
Steel Protective Coatingsq. ft.18,30411,7014,8851,230488
Reinforced Concrete Pier Caplinear ft.6700614560
Joints
Compression Jointlinear ft.1,22106325890
Bearings
Movable Bearingeach21877129120
Steel Protective Coatingsq. ft.1862168142
Fixed Bearingeach119011900
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.2,15602,068880
Steel Protective Coatingsq. ft.9,30508,93634326
Reinforced Concrete Bridge Raillinear ft.2,33102,291400
Deck
Reinforced Concrete Slabsq. ft.14,35113,293985730
Wearing Surfacessq. ft.9,77109,753180