Share:

NORTH BUS PRKG BR over BROADWAY

Map

Coordinates:
+40.84883, -73.93719
40°50'56" N, 73°56'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NORTH BUS PRKG BR over BROADWAY
Structure number:000000005522570
Location:AT JCT US 9 & I95
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:120.4 ft. [36.7 m]
Total length:122.4 ft. [37.3 m]
Roadway width between curbs:27.6 ft. [8.4 m]
Deck width edge-to-edge:51.8 ft. [15.8 m]
Vertical clearance below bridge:29.5 ft. [9.0 m]
Skew angle:40°
Owner:Local Toll Authority [32]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:75.4
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$3,914,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017FairFairSatisfactorySatisfactory-75.4
June 2015FairFairSatisfactorySatisfactory-95.0
June 2013FairFairSatisfactoryGood20095.0
June 2011FairFairSatisfactoryGood20097.0
June 2009FairFairSatisfactoryGood20097.0
June 2007FairSatisfactoryGoodGood20098.0
June 2005FairSatisfactoryGoodGood20098.0
August 2003FairSatisfactoryGoodGood20098.0
August 2001FairSatisfactoryGoodGood20093.0
July 1999FairSatisfactoryGoodGood20093.0
August 1997FairSatisfactoryFairSatisfactory20082.0
August 1995PoorFairPoorFair20065.0
September 1993PoorFairPoorFair20065.0
July 1991FairFairFairFair20069.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.245024500
Steel Protective Coatingsq. ft.2,45001,3701,0800
Deck
Reinforced Concrete Decksq. ft.6,14403,3692,7750
Wearing Surfacessq. ft.3,37002,8705000
Superstructure
Steel Floor Beamlinear ft.732073200
Steel Protective Coatingsq. ft.3,30801,6541,6540
Substructure
Reinforced Concrete Abutmentlinear ft.135013500
Joints
Strip Seal Jointlinear ft.7107100
Other Jointlinear ft.6400640
Bearings
Movable Bearingeach20110
Steel Protective Coatingsq. ft.40004
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.245002450