Share:

AMSTERDAM AVENUE over RTE I95

Map

Coordinates:
+40.84661, -73.93199
40°50'48" N, 73°55'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:AMSTERDAM AVENUE over RTE I95
Structure number:000000005522630
Location:0.35MI E OF 95I & US 9
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:114.8 ft. [35.0 m]
Total length:220.2 ft. [67.1 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:100.1 ft. [30.5 m]
Vertical clearance above deck:15.7 ft. [4.8 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Owner:Local Toll Authority [32]
Year built:1959
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:22,947 [as of 2011]
Truck traffic:12% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:79.7
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$23,147,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairFairFairFair2294779.7
August 2015FairFairFairFair2466861.0
August 2013FairFairSatisfactoryFair583862.5
August 2011FairFairSatisfactoryFair583862.5
August 2009FairFairSatisfactorySatisfactory2227872.5
July 2007FairFairSatisfactorySatisfactory2740672.2
July 2005FairFairSatisfactorySatisfactory583873.6
July 2003FairFairSatisfactorySatisfactory583873.6
August 2001FairFairSatisfactorySatisfactory583873.6
August 1999FairFairSatisfactorySatisfactory583873.6
August 1997FairFairFairFair583862.5
August 1995PoorPoorPoorPoor583845.8
August 1993PoorPoorFairPoor583845.8
April 1992PoorPoorPoorFair583859.2
March 1992PoorSatisfactoryPoorFair583866.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,74001,74000
Steel Protective Coatingsq. ft.41,341031,0068,2682,067
Deck
Reinforced Concrete Decksq. ft.21,800015,2606,5400
Wearing Surfacessq. ft.13,080012,9781020
Substructure
Reinforced Concrete Pier Walllinear ft.100089110
Reinforced Concrete Abutmentlinear ft.200019190
Joints
Strip Seal Jointlinear ft.2000180200
Bearings
Movable Bearingeach1601150
Steel Protective Coatingsq. ft.32016016
Fixed Bearingeach80800
Steel Protective Coatingsq. ft.1601060
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.205000205
Steel Protective Coatingsq. ft.296000296
Reinforced Concrete Bridge Raillinear ft.384038220