Share:

SR176 over RAMP J,SB TO JENNINGS RD

Map

Coordinates:
+41.45444, -81.69056
41°27'16" N, 81°41'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR176 over RAMP J,SB TO JENNINGS RD
Structure number:1810030
Location:2 MI S I-71
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:65.9 ft. [20.1 m]
Total length:178.2 ft. [54.3 m]
Roadway width between curbs:113.9 ft. [34.7 m]
Deck width edge-to-edge:117.8 ft. [35.9 m]
Vertical clearance below bridge:15.1 ft. [4.6 m]
Skew angle:55°
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:75,259 [as of 2015]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:87.5

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
May 201687.5FairSatisfactoryGoodGood-75259
June 201587.5FairSatisfactoryGoodGood-75643
June 201487.5FairSatisfactoryGoodGood-75643
June 201387.5FairSatisfactoryGoodGood-75643
May 201287.5FairSatisfactoryGoodGood-75643
August 201187.5FairSatisfactoryGoodGood-75643
March 201087.6FairSatisfactoryGoodGood-74232
May 200987.6FairSatisfactoryGoodGood-74232
June 200887.6FairSatisfactoryGoodGood-74232
August 200787.8FairSatisfactoryGoodGood-72710
November 200687.8FairSatisfactoryGoodGood-72710
October 200587.8FairSatisfactoryGoodGood-72710
July 200494.9FairSatisfactoryGoodGood-1000
April 200394.9GoodGoodGoodGood-1000
May 200294.9FairSatisfactoryGoodGood-1000
July 200090.0FairSatisfactoryGoodGood-50429
September 199993.1FairSatisfactoryGoodGood-18940
August 199893.1FairSatisfactoryGoodGood-18940
August 199793.1FairSatisfactorySatisfactoryGood-18940
November 199693.1FairSatisfactorySatisfactoryGood-18940
October 199593.5GoodGoodGoodGood-18940
August 199493.5GoodVery GoodVery GoodVery Good-18940
September 199393.5FairSatisfactoryGoodGood-18940
July 199265.7PoorSatisfactoryGoodPoorSD18940
June 199165.7PoorSatisfactoryGoodPoorSD18940

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2,9412,79314800
Deck
Reinforced Concrete Decksq. ft.20,99015,4975,2832100
Substructure
Reinforced Concrete Columneach2019100
Reinforced Concrete Abutmentlinear ft.4123922000
Reinforced Concrete Pier Caplinear ft.4123922000
Joints
Assembly without Seal Jointlinear ft.236023600
Bearings
Movable Bearingeach68343400
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.35626871170