Share:

SR-176J JENN.FRWY over VALLY RD,BIG CR,W&LE,CSX

Map

Coordinates:
+41.44639, -81.68861
41°26'47" N, 81°41'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR-176J JENN.FRWY over VALLY RD,BIG CR,W&LE,CSX
Structure number:1810189
Location:^ 1.5 MI NORTH OF IR-480
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:178.5 ft. [54.4 m]
Total length:1101.8 ft. [335.8 m]
Roadway width between curbs:120.4 ft. [36.7 m]
Deck width edge-to-edge:124.7 ft. [38.0 m]
Vertical clearance below bridge:24.3 ft. [7.4 m]
Skew angle:25°
Owner:State Highway Agency [01]
Year built:1997
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:8
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:78,054 [as of 2015]
Truck traffic:3% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Superior to present desirable criteria [9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:92.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
September 201692.7GoodVery GoodVery GoodVery Good-78054
September 201593.3GoodVery GoodVery GoodVery Good-71209
November 201493.3GoodVery GoodVery GoodVery Good-71209
October 201393.3GoodGoodVery GoodGood-71209
November 201293.3FairGoodVery GoodSatisfactory-71209
October 201193.3FairGoodVery GoodSatisfactory-71209
June 201093.2FairGoodVery GoodSatisfactory-72710
December 200993.2FairGoodVery GoodSatisfactory-72710
September 200893.2GoodGoodVery GoodGood-72710
November 200793.2GoodGoodVery GoodGood-72710
October 200693.2GoodGoodVery GoodGood-72710
December 200593.2GoodGoodVery GoodGood-72710
December 200494.1GoodGoodVery GoodGood-62480
December 200394.1GoodGoodVery GoodGood-62480
December 200294.1GoodGoodVery GoodGood-62480
November 200194.1GoodGoodVery GoodGood-62480
July 200095.3GoodGoodVery GoodVery Good-50429

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.16,52116,521000
Deck
Reinforced Concrete Decksq. ft.137,546130,4487,09800
Substructure
Reinforced Concrete Columneach5250200
Reinforced Concrete Abutmentlinear ft.2762631300
Reinforced Concrete Pier Caplinear ft.9658699600
Joints
Strip Seal Jointlinear ft.6003901206030
Bearings
Movable Bearingeach1321062600
Bridge Rail