Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LANE SW over UP I490-ES&I90-R, DN I49
Structure number:1812033
Location:.19 MI. E. OF JCT. I-90
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:104.0 ft. [31.7 m]
Total length:313.0 ft. [95.4 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Vertical clearance above deck:15.4 ft. [4.7 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,000 [as of 2002]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:88.1

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201688.1FairSatisfactoryGoodSatisfactory-1000
November 201588.1FairSatisfactoryGoodSatisfactory-1000
December 201486.1FairSatisfactoryGoodSatisfactoryFO1000
December 201386.1FairSatisfactoryGoodSatisfactoryFO1000
December 201286.1FairSatisfactoryGoodSatisfactoryFO1000
October 201186.1FairSatisfactoryGoodSatisfactoryFO1000
May 201086.1FairSatisfactoryGoodSatisfactoryFO1000
May 200986.1FairSatisfactoryGoodSatisfactoryFO1000
June 200886.1FairSatisfactoryGoodSatisfactoryFO1000
July 200788.1FairSatisfactoryGoodSatisfactory-1000
August 200688.1FairSatisfactoryGoodSatisfactory-1000
June 200588.1FairSatisfactoryGoodSatisfactory-1000
May 200488.1FairSatisfactoryGoodSatisfactory-1000
August 200388.1FairSatisfactoryGoodSatisfactory-1000
August 200290.2FairSatisfactorySatisfactorySatisfactory-1000
October 200190.2FairSatisfactorySatisfactorySatisfactory-1000
July 200038.0PoorFairPoorSatisfactorySD71410
December 199939.0PoorSatisfactoryPoorSatisfactorySD71410
September 199857.7FairSatisfactoryFairGood-71410
September 199670.4FairSatisfactoryGoodGood-71410
November 199571.9FairSatisfactoryGoodGoodFO71410
September 199478.2FairSatisfactoryGoodGoodFO8260
July 199376.2FairSatisfactorySatisfactoryGoodFO8260
August 199277.2FairFairSatisfactoryGoodFO8260
September 199175.1PoorPoorGoodVery GoodSD8260

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,5651,40815700
Deck
Reinforced Concrete Decksq. ft.11,3479,5061,24858013
Wearing Surfacessq. ft.9,3904,6954,69500
Substructure
Reinforced Concrete Columneach10100
Reinforced Concrete Pier Walllinear ft.2216510
Reinforced Concrete Abutmentlinear ft.7370300
Joints
Assembly without Seal Jointlinear ft.7207200
Bearings
Movable Bearingeach1501500
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.6265645660