Share:

I-70 over OVER 315 AND RAMPS

Map

Coordinates:
+39.95094, -83.01779
39°57'03" N, 83°01'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-70 over OVER 315 AND RAMPS
Structure number:2504677
Location:1.03 MI E OF US62
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:110.9 ft. [33.8 m]
Total length:706.7 ft. [215.4 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Vertical clearance below bridge:32.8 ft. [10.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:9
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:27,081 [as of 2015]
Truck traffic:13% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:89.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairGoodSatisfactorySatisfactory2708189.5
May 2016FairGoodSatisfactorySatisfactory2708189.5
May 2015FairGoodSatisfactorySatisfactory4622587.6
June 2014FairGoodGoodSatisfactory4622587.6
August 2013FairGoodGoodSatisfactory4622587.6
August 2012FairGoodGoodSatisfactory4622588.6
October 2011FairGoodGoodSatisfactory4622588.6
July 2010FairGoodGoodSatisfactory5084588.1
August 2009GoodGoodGoodGood5084588.2
July 2008GoodGoodGoodGood5084588.2
November 2007GoodGoodGoodGood5084588.2
August 2006GoodGoodGoodGood7085586.2
August 2005GoodGoodGoodGood7085586.2
March 2005GoodGoodGoodGood7085586.2
August 2003GoodGoodGoodGood7688085.6
September 2002GoodGoodGoodGood6889486.4
February 2000GoodGoodGoodGood6889486.4
November 1998GoodGoodGoodGood6889486.4
October 1996FairGoodGoodSatisfactory6424486.8
September 1995FairGoodGoodSatisfactory6424488.1
July 1994FairSatisfactorySatisfactorySatisfactory6424488.1
June 1993FairFairSatisfactoryFair6424475.2
June 1992FairSatisfactoryGoodFair6424476.3
May 1991FairSatisfactoryGoodFair6424476.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.4,2404,2103000
Steel Protective Coatingsq. ft.51,11850,75736100
Deck
Reinforced Concrete Decksq. ft.31,09730,6973006040
Wearing Surfacessq. ft.29,68029,59050040
Superstructure
Steel Pin or Pin & Hangar Assemblyeach60600
Substructure
Reinforced Concrete Columneach2320300
Reinforced Concrete Abutmentlinear ft.8872880
Reinforced Concrete Pier Caplinear ft.352349030
Joints
Assembly without Seal Jointlinear ft.132884400
Bearings
Movable Bearingeach60470130
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,414101,4130