Share:

71NBTO270WBRAMP over OVER RAMP 71NB-270WB

Map

Coordinates:
+40.11000, -82.97472
40°06'36" N, 82°58'29" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:71NBTO270WBRAMP over OVER RAMP 71NB-270WB
Structure number:2511460
Location:0.16 MI E OF I71
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:75.1 ft. [22.9 m]
Total length:185.0 ft. [56.4 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:104,140 [as of 1990]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:76.9

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201676.9FairFairSatisfactorySatisfactoryFO104140
October 201576.9FairFairSatisfactorySatisfactoryFO104140
September 201476.9FairFairSatisfactorySatisfactoryFO104140
August 201376.9FairFairSatisfactorySatisfactoryFO104140
August 201276.9FairFairSatisfactorySatisfactoryFO104140
October 201178.1FairSatisfactorySatisfactorySatisfactoryFO104140
September 201078.1FairSatisfactorySatisfactorySatisfactoryFO104140
October 200978.1FairSatisfactorySatisfactorySatisfactoryFO104140
December 200878.1FairSatisfactorySatisfactorySatisfactoryFO104140
October 200778.1FairSatisfactorySatisfactorySatisfactoryFO104140
October 200678.1FairSatisfactorySatisfactorySatisfactoryFO104140
December 200578.1FairSatisfactorySatisfactorySatisfactoryFO104140
October 200478.1FairSatisfactorySatisfactorySatisfactoryFO104140
October 200378.1FairSatisfactorySatisfactorySatisfactoryFO104140
October 200278.1FairGoodSatisfactorySatisfactoryFO104140
August 200080.1FairGoodSatisfactorySatisfactoryFO104140
October 199980.1FairGoodSatisfactorySatisfactoryFO104140
August 199884.6FairSatisfactorySatisfactorySatisfactory-104140
July 199684.6FairGoodGoodSatisfactory-104140
November 199586.7FairSatisfactoryGoodSatisfactory-104140
October 199485.6FairFairGoodSatisfactory-104140
July 199285.6FairFairGoodSatisfactory-104140
July 199185.6FairFairGoodSatisfactory-104140

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,11001,086240
Deck
Reinforced Concrete Decksq. ft.7,7727,65212000
Wearing Surfacessq. ft.7,0306,93010000
Substructure
Reinforced Concrete Columneach1010000
Reinforced Concrete Abutmentlinear ft.8518400
Reinforced Concrete Pier Caplinear ft.8585000
Joints
Assembly without Seal Jointlinear ft.84007212
Bearings
Movable Bearingeach24012120
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.370003700