Share:

LUC-65 over MAUMEE R CSX RR SUMMIT

Map

Coordinates:
+41.65833, -83.51000
41°39'30" N, 83°30'36" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LUC-65 over MAUMEE R CSX RR SUMMIT
Structure number:4805917
Location:JCT. MAUMEE RIVER
Purpose:Carries highway over highway and waterway
Route classification:Local (Urban) [19]
Length of largest span:222.1 ft. [67.7 m]
Total length:1680.2 ft. [512.1 m]
Roadway width between curbs:58.1 ft. [17.7 m]
Deck width edge-to-edge:84.0 ft. [25.6 m]
Vertical clearance below bridge:39.4 ft. [12.0 m]
Owner:State Highway Agency [01]
Year built:1956
Year reconstructed:1980
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Main span material:Steel [3]
Main span design:Movable - Bascule [16]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,612 [as of 2015]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:55.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$2,500,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairSatisfactoryFairSatisfactory961255.5
December 2016FairSatisfactoryFairSatisfactory961255.5
December 2015FairSatisfactorySatisfactorySatisfactory704072.1
December 2014FairSatisfactorySatisfactorySatisfactory704072.1
December 2013PoorSatisfactoryPoorFair704044.5
December 2012PoorSatisfactoryPoorFair704044.5
December 2011PoorSatisfactoryPoorFair704044.5
March 2010PoorSatisfactoryPoorFair668044.5
March 2009PoorSatisfactoryPoorFair668044.5
April 2008PoorSatisfactoryPoorFair668044.5
March 2007PoorSatisfactoryPoorFair5237044.5
February 2006PoorSatisfactoryPoorFair5237043.5
March 2005PoorSatisfactoryPoorFair5237043.5
February 2004PoorSatisfactoryPoorFair6283043.5
March 2003PoorSatisfactoryPoorFair6283043.5
February 2002PoorSatisfactoryPoorFair6283043.5
March 2001PoorSatisfactoryPoorFair6283043.5
February 2000PoorSatisfactoryPoorFair6299043.5
February 1999PoorSatisfactoryPoorFair6299043.5
March 1998PoorSatisfactoryPoorFair6334043.5
April 1997PoorFairPoorPoor6334042.5
June 1996PoorFairPoorPoor6334042.5
June 1995PoorFairPoorFair5755042.5
August 1994PoorFairPoorFair5755042.5
October 1993PoorFairSatisfactoryPoor5755042.5
August 1992PoorFairFairPoor5755042.5
August 1991PoorFairFairPoor5755042.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.6,72006,0486720
Steel Stringerlinear ft.10,080010,08000
Deck
Reinforced Concrete Decksq. ft.141,120128,12012,0001,0000
Wearing Surfacessq. ft.97,440097,44000
Superstructure
Steel Floor Beamlinear ft.7,17807,17800
Substructure
Reinforced Concrete Columneach107300
Reinforced Concrete Pier Walllinear ft.570057000
Reinforced Concrete Abutmentlinear ft.164016400
Reinforced Concrete Pier Caplinear ft.2251854000
Joints
Assembly without Seal Jointlinear ft.408408000
Bearings
Movable Bearingeach5405004
Bridge Rail