Share:

SR 57 over BLOCKERS CREEK

Map

Coordinates:
+41.00722, -81.75250
41°00'26" N, 81°45'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 57 over BLOCKERS CREEK
Structure number:5201802
Location:1.87 MI SOUTH OF I 76
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:26.9 ft. [8.2 m]
Total length:80.1 ft. [24.4 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Skew angle:22°
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,443 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:34.5 tons [31.4 metric tons]
Sufficiency rating:82.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201682.0FairFairFairSatisfactory-9443
September 201581.1FairFairFairSatisfactory-10925
September 201481.1FairFairFairSatisfactory-10925
September 201381.1FairFairFairSatisfactory-10925
June 201281.1FairFairFairSatisfactory-10925
August 201181.1FairFairFairSatisfactory-10925
July 201080.7FairFairFairSatisfactory-11562
September 200980.8FairFairFairSatisfactory-11562
October 200880.8FairFairFairSatisfactory-11562
November 200780.9FairFairFairSatisfactory-11309
December 200681.2FairFairFairSatisfactory-10768
December 200581.2FairFairFairSatisfactory-10768
November 200494.2FairSatisfactorySatisfactorySatisfactory-10768
August 200394.2FairSatisfactorySatisfactorySatisfactory-10768
April 200294.2FairSatisfactorySatisfactorySatisfactory-10768
July 200094.2FairSatisfactorySatisfactorySatisfactory-10768
March 199995.3FairSatisfactorySatisfactorySatisfactory-8598
April 199895.3FairSatisfactorySatisfactorySatisfactory-8598
May 199795.3FairSatisfactorySatisfactorySatisfactory-8598
June 199693.3FairSatisfactorySatisfactorySatisfactory-8598
August 199595.2FairSatisfactorySatisfactorySatisfactory-8598
August 199492.2FairSatisfactorySatisfactorySatisfactory-8598
June 199392.2FairSatisfactorySatisfactorySatisfactory-8598
July 199294.5FairSatisfactorySatisfactorySatisfactory-7956
May 199194.5GoodVery GoodVery GoodVery Good-7956

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Reinforced Concrete Columneach1615100
Reinforced Concrete Abutmentlinear ft.95444740
Reinforced Concrete Pier Caplinear ft.9591400
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.160160000
Deck
Reinforced Concrete Slabsq. ft.3,5201,69678496080
Wearing Surfacessq. ft.3,5202,8163523520