Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 35 over TWP RD 125
Structure number:7101686
Location:3.00 MI W OF SR 104
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:32.2 ft. [9.8 m]
Total length:92.9 ft. [28.3 m]
Roadway width between curbs:37.7 ft. [11.5 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Vertical clearance below bridge:13.8 ft. [4.2 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:6,125 [as of 2015]
Truck traffic:16% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:89.1

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201689.1FairGoodGoodSatisfactoryFO6125
November 201588.6GoodGoodGoodGoodFO7712
November 201488.6GoodGoodGoodGoodFO7712
October 201388.6FairSatisfactorySatisfactoryGoodFO7712
November 201286.3FairSatisfactorySatisfactoryGoodFO8560
October 201186.3FairSatisfactorySatisfactoryGoodFO8560
December 201087.0FairSatisfactorySatisfactorySatisfactoryFO6330
December 200987.0FairSatisfactorySatisfactorySatisfactoryFO6330
December 200887.0FairSatisfactorySatisfactorySatisfactoryFO6330
December 200787.0FairSatisfactoryGoodSatisfactoryFO6330
October 200687.0GoodGoodGoodGoodFO6335
September 200587.0GoodGoodGoodGoodFO6335
September 200487.0GoodGoodGoodGoodFO6335
September 200387.2GoodGoodGoodVery GoodFO5870
August 200287.2GoodGoodGoodVery GoodFO5870
June 200087.8GoodGoodGoodVery GoodFO3795
August 199987.8GoodGoodGoodVery GoodFO3795
June 199887.8GoodVery GoodVery GoodVery GoodFO3795
June 199787.8GoodGoodGoodGoodFO3795
May 199696.9GoodGoodGoodGood-3795
July 199596.9FairSatisfactorySatisfactoryGood-3795
September 199496.9GoodGoodGoodGood-3795
October 199395.7GoodGoodGoodGood-7680
November 199295.7GoodGoodGoodGood-7680
November 199195.7GoodGoodGoodGood-7680

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.85256000
Joints
Pourable Jointlinear ft.84701400
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1861652010
Deck
Reinforced Concrete Slabsq. ft.3,9063,680214120
Wearing Surfacessq. ft.3,5033,35315000