S.H. 11 over HOMINY CREEK
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+36.25909, -95.9736836°15'33" N, 95°58'25" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | S.H. 11 over HOMINY CREEK |
Structure number: | 095350000000000 |
Old structure number: | 7236 0743 X (from 1992 edition) |
Location: | 7.4 MI S WASH. C/L |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 160.1 ft. [48.8 m] |
Total length: | 404.9 ft. [123.4 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 29.5 ft. [9.0 m] |
Vertical clearance above deck: | 15.1 ft. [4.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 1940 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 18 / H 20 [4] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: September 2015
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 5,800 [as of 2014] |
Truck traffic: | 15% of total traffic |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 46.2 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $4,900,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2015 | Poor | Poor | Fair | Fair | 5800 | 46.2 |
September 2013 | Poor | Poor | Fair | Fair | 5800 | 46.2 |
October 2011 | Poor | Poor | Fair | Fair | 5800 | 47.7 |
December 2009 | Poor | Poor | Fair | Fair | 5800 | 47.7 |
December 2007 | Poor | Poor | Fair | Poor | 5600 | 31.7 |
August 2006 | Poor | Poor | Fair | Poor | 5700 | 31.7 |
July 2005 | Poor | Poor | Fair | Fair | 5600 | 33.2 |
January 2004 | Poor | Poor | Fair | Fair | 5360 | 33.2 |
October 2000 | Poor | Poor | Fair | Fair | 5170 | 33.2 |
September 2000 | Poor | Poor | Satisfactory | Poor | 5170 | 18.2 |
September 1998 | Poor | Serious | Satisfactory | Poor | 5170 | 23.9 |
October 1996 | Poor | Serious | Satisfactory | Fair | 5080 | 38.9 |
December 1994 | Poor | Fair | Poor | Fair | 6800 | 35.1 |
July 1992 | Poor | Fair | Poor | Fair | 6600 | 35.1 |
July 1990 | Poor | Poor | Poor | Fair | 6600 | 33.1 |