Share:

I-44 over 163 E. AVE. UNDER

This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.

Map

Coordinates:
+36.16334, -95.79443
36°09'48" N, 95°47'40" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-44 over 163 E. AVE. UNDER
Structure number:140990000000000
Location:1.8 MI E JCT I-244
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:40.0 ft. [12.2 m]
Total length:101.1 ft. [30.8 m]
Roadway width between curbs:37.1 ft. [11.3 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Vertical clearance below bridge:16.1 ft. [4.9 m]
Owner:State Highway Agency [01]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2008

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:34,300 [as of 2008]
Truck traffic:12% of total traffic
Deck condition:Serious [3 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$2,083,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2008PoorSeriousFairSatisfactory3430077.0
July 1998PoorCriticalSatisfactoryFair3416078.0