Share:

N2330 over YELLOWSTONE CREEK

Map

Coordinates:
+36.97881, -98.86697
36°58'44" N, 98°52'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:N2330 over YELLOWSTONE CREEK
Structure number:161870000000000
Location:12.6 N 2.6 E OF CORA
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:20.0 ft. [6.1 m]
Total length:641.1 ft. [195.4 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:25.9 ft. [7.9 m]
Owner:County Highway Agency [02]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:32
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: January 2016

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:100 [as of 2015]
Truck traffic:15% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:24.0 tons [21.8 metric tons]
Sufficiency rating:85.7
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,504,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
January 201685.7FairGoodSatisfactoryGood-100
January 201485.7FairGoodSatisfactoryGood-100
January 201285.7FairGoodSatisfactoryGood-100
February 201085.7FairGoodSatisfactoryGood-100
March 200885.7FairGoodSatisfactoryGood-100
April 200685.7FairGoodSatisfactoryGood-100
January 200489.7FairGoodSatisfactoryGood-100
December 200189.7FairGoodSatisfactoryGood-100
November 199976.0FairGoodSatisfactorySatisfactory-100
September 199776.0FairGoodGoodSatisfactory-100
August 199583.5GoodGoodGoodGood-100
August 199383.5GoodGoodGoodGood-100
July 199183.5FairSatisfactorySatisfactorySatisfactory-100