Share:

S.H. 112 over POTEAU RIVER O'FLOW

Map

Coordinates:
+35.11284, -94.60207
35°06'46" N, 94°36'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S.H. 112 over POTEAU RIVER O'FLOW
Structure number:178960000000000
Location:2.08 NE JCT US-271
Purpose:Carries highway over relief for waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:49.9 ft. [15.2 m]
Total length:151.9 ft. [46.3 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:48.9 ft. [14.9 m]
Owner:State Highway Agency [01]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:8,900 [as of 2015]
Truck traffic:15% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:83.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$3,125,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016FairSatisfactoryGoodGood890083.0
July 2014FairSatisfactoryGoodGood890083.0
April 2012FairSatisfactoryGoodGood890084.0
May 2010FairSatisfactoryFairGood880073.0
May 2008FairSatisfactoryFairGood830073.0
December 2005FairSatisfactoryFairGood810073.0
December 2003FairSatisfactoryFairGood763073.0
March 2002FairSatisfactoryFairGood752072.0
April 2000FairSatisfactoryFairGood732072.4
October 1997GoodGoodVery GoodGood700085.8
August 1995GoodGoodGoodGood600087.6
April 1993GoodGoodGoodGood600087.6
April 1991FairSatisfactorySatisfactorySatisfactory480091.7