Share:

US 26 (HWY 026) over WILLAMETTE RIVER/OPR

Map

Coordinates:
+45.50146, -122.66173
45°30'05" N, 122°39'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 26 (HWY 026) over WILLAMETTE RIVER/OPR
Structure number:05054 026 00077
Location:IN SE PORTLAND
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:535.1 ft. [163.1 m]
Total length:3653.1 ft. [1113.4 m]
Roadway width between curbs:43.0 ft. [13.1 m]
Deck width edge-to-edge:51.8 ft. [15.8 m]
Vertical clearance below bridge:128.9 ft. [39.3 m]
Owner:State Highway Agency [01]
Year built:1926
Year reconstructed:2000
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:M 18 / H 20 [4]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:50,600 [as of 2014]
Truck traffic:2% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:32.9 tons [29.9 metric tons]
Inventory rating:19.9 tons [18.1 metric tons]
Sufficiency rating:32.4
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$31,448,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201532.4FairSatisfactoryFairSatisfactoryFO50600
March 201332.4FairSatisfactoryFairSatisfactoryFO46300
August 200932.4FairSatisfactoryFairSatisfactoryFO55700
August 200732.4FairSatisfactoryFairSatisfactory-58600
June 200453.8FairSatisfactorySatisfactorySatisfactory-58700
June 200242.2FairSatisfactorySatisfactoryFairFO58000
June 200050.2FairFairSatisfactorySatisfactoryFO55800
June 199851.4FairSatisfactorySatisfactorySatisfactoryFO55800
June 199651.4GoodGoodGoodGoodFO55800
June 199450.6GoodGoodGoodGoodFO55800
June 199257.8GoodGoodGoodGoodFO55800
June 199055.1GoodGoodGoodGoodFO59000

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.18,4887,39610,1689240
Steel Stringerlinear ft.18,180018,18000
Steel Protective Coatingsq. ft.96,626094,6941,9320
Reinforced Concrete Stringerlinear ft.7,7807,00277800
Deck
Reinforced Concrete Decksq. ft.189,23047,30828,384113,5380
Wearing Surfacessq. ft.110,3400110,34000
Superstructure
Steel Trusslinear ft.1,292001,2920
Steel Protective Coatingsq. ft.11,86800011,868
Steel Archlinear ft.2,354002,3540
Steel Protective Coatingsq. ft.134,150000134,150
Steel Floor Beamlinear ft.6,78206,78200
Steel Protective Coatingsq. ft.56,961055,8221,1390
Reinforced Concrete Floor Beamlinear ft.2,9907482,24200
Deck
Reinforced Concrete Top Flangesq. ft.76,92376,923000
Superstructure
Steel Gusset Plateeach1,2805765121920
Steel Protective Coatingsq. ft.23,83510,7269,53403,575
Substructure
Reinforced Concrete Columneach96771450
Reinforced Concrete Pier Walllinear ft.207020700
Reinforced Concrete Abutmentlinear ft.103782500
Reinforced Concrete Pile Cap/Footinglinear ft.1313000
Reinforced Concrete Pier Caplinear ft.2,0205051,4141010
Joints
Pourable Jointlinear ft.104520052
Compression Jointlinear ft.823082300
Assembly with Sealeach102465600
Bearings
Movable Bearingeach2802800
Fixed Bearingeach60600
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7,4127,412000
Steel Protective Coatingsq. ft.45,96045,960000