Share:

OR 99W (HWY 001W) over VICTORY BLVD

Map

Coordinates:
+45.59516, -122.68547
45°35'43" N, 122°41'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:OR 99W (HWY 001W) over VICTORY BLVD
Structure number:06686C01WX00550
Location:5.5 MI N OF PORTLAND CC
Purpose:Carries highway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:30.8 ft. [9.4 m]
Total length:152.9 ft. [46.6 m]
Roadway width between curbs:61.4 ft. [18.7 m]
Deck width edge-to-edge:64.3 ft. [19.6 m]
Vertical clearance below bridge:15.1 ft. [4.6 m]
Owner:State Highway Agency [01]
Year built:1962
Year reconstructed:1992
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:14,000 [as of 2014]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:31.0 tons [28.2 metric tons]
Inventory rating:23.9 tons [21.7 metric tons]
Sufficiency rating:71.7
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$1,643,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201671.7FairSatisfactorySatisfactoryFairFO14000
February 201471.9FairSatisfactorySatisfactoryFairFO12500
February 201282.2FairSatisfactorySatisfactorySatisfactoryFO12500
January 201181.7FairSatisfactorySatisfactorySatisfactoryFO16300
January 200994.4FairSatisfactorySatisfactorySatisfactoryFO16300
January 200794.4FairSatisfactorySatisfactorySatisfactoryFO15862
January 200583.3FairSatisfactorySatisfactoryFairFO15400
January 200348.7PoorGoodSatisfactorySeriousSD15400
January 200148.8PoorGoodSatisfactorySerious-15000
January 199994.7FairGoodGoodSatisfactory-13400
January 199794.7GoodGoodGoodGood-13400
January 199595.0GoodGoodGoodGood-12300
January 199393.0FairGoodSatisfactoryGood-12300

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.3,05502,7403150
Deck
Reinforced Concrete Top Flangesq. ft.9,3979,24715000
Wearing Surfacessq. ft.9,3979,397000
Substructure
Steel Columneach2121000
Steel Protective Coatingsq. ft.4,2164,216000
Timber Columneach3424460
Timber Abutmentlinear ft.130130000
Steel Pier Caplinear ft.2571906700
Steel Protective Coatingsq. ft.7,8675,8172,05000
Timber Pier Caplinear ft.7800780
Joints
Other Jointlinear ft.44922422500
Bridge Rail