Share:

US 26 (HWY 047) over RIGID FRAME O'XING JEFF

Map

Coordinates:
+45.51562, -122.69969
45°30'56" N, 122°41'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 26 (HWY 047) over RIGID FRAME O'XING JEFF
Structure number:09391 047 07341
Location:1.1 MI W OF PORTLAND CC
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:29.9 ft. [9.1 m]
Total length:33.5 ft. [10.2 m]
Roadway width between curbs:91.9 ft. [28.0 m]
Deck width edge-to-edge:608.0 ft. [185.3 m]
Vertical clearance below bridge:16.1 ft. [4.9 m]
Skew angle:50°
Owner:State Highway Agency [01]
Year built:1968
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,400 [as of 2014]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:59.8 tons [54.4 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:78.9
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$384,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201678.9FairSatisfactorySatisfactoryFairFO13400
October 201480.1FairSatisfactorySatisfactoryFairFO10800
October 201280.1FairSatisfactorySatisfactoryFairFO10800
September 201070.0FairSatisfactorySatisfactoryFairFO67800
September 200870.0FairSatisfactorySatisfactoryFairFO67800
September 200666.0FairSatisfactorySatisfactorySatisfactoryFO138020
September 200454.0FairFairFairFairFO138020
September 200250.0FairFairFairGoodFO134000
September 200070.5FairSatisfactoryGoodGoodFO12600
September 199888.9Good-GoodGoodFO12600
September 199688.9Good-GoodGoodFO12600
September 19940.0Good-GoodGood-12600
September 19920.0Good-GoodGood-12600
October 19900.0Good-GoodGood-12300

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Reinforced Concrete Abutmentlinear ft.1,21653906770
Deck
Reinforced Concrete Slabsq. ft.20,26718,077602,1300