Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | HIGH DECK ROAD over SOUTH SANTIAM RIVER |
Structure number: | 14025 091300167 |
Location: | 020 MI W CASCADIA PARK |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 105.0 ft. [32.0 m] |
Total length: | 173.9 ft. [53.0 m] |
Roadway width between curbs: | 18.0 ft. [5.5 m] |
Deck width edge-to-edge: | 19.4 ft. [5.9 m] |
Vertical clearance above deck: | 14.4 ft. [4.4 m] |
Owner: | County Highway Agency [02] |
Year built: | 1945 |
Year reconstructed: | 1991 |
Historic significance: | Bridge is on the National Register of Historic Places [1] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Wood or timber [7] |
Main span design: | Truss - Thru [10] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for other load-capacity restriction [R] |
Average daily traffic: | 158 [as of 2010] |
Truck traffic: | 15% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 48.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $980,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Good | Satisfactory | Satisfactory | 158 | 48.4 |
August 2015 | Fair | Good | Satisfactory | Satisfactory | 158 | 48.4 |
November 2013 | Fair | Good | Satisfactory | Satisfactory | 158 | 48.4 |
February 2012 | Poor | Good | Poor | Satisfactory | 158 | 23.0 |
November 2011 | Fair | Good | Satisfactory | Satisfactory | 158 | 43.4 |
October 2009 | Fair | Good | Good | Satisfactory | 158 | 43.4 |
October 2007 | Good | Very Good | Good | Good | 158 | 43.4 |
October 2005 | Good | Very Good | Good | Good | 153 | 43.4 |
December 2003 | Good | Very Good | Good | Good | 153 | 71.9 |
September 2001 | Good | Very Good | Good | Good | 153 | 71.9 |
September 1999 | Good | Very Good | Good | Good | 150 | 71.9 |
December 1997 | Good | Very Good | Good | Good | 150 | 71.9 |
January 1996 | Good | Very Good | Good | Good | 150 | 71.9 |
November 1993 | Good | Very Good | Good | Good | 150 | 73.9 |
December 1991 | Good | Very Good | Very Good | Good | 220 | 73.9 |
July 1991 | Fair | Fair | Fair | Satisfactory | 50 | 56.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Timber Stringer | linear ft. | 1,470 | 1,370 | 100 | 0 | 0 |
Deck |
Prestressed Concrete Deck | sq. ft. | 1,346 | 1,346 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,346 | 1,277 | 0 | 69 | 0 |
Superstructure |
Timber Truss | linear ft. | 210 | 46 | 129 | 35 | 0 |
Timber Floor Beam | linear ft. | 168 | 168 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 2 | 1 | 1 | 0 |
Reinforced Concrete Abutment | linear ft. | 48 | 48 | 0 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 96 | 48 | 48 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 60 | 55 | 5 | 0 | 0 |
Joints |
Other Joint | linear ft. | 76 | 41 | 35 | 0 | 0 |
Deck |
Timber Deck | sq. ft. | 2,021 | 2,021 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 2,021 | 2,021 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 20 | 20 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 348 | 308 | 40 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,158 | 1,726 | 0 | 432 | 0 |