Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:JUMPOFF JOE CRK RD over JACKS CREEK
Structure number:33C30 201000267
Location:T34S-R5W-S32 JOSEPHINE CO
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:24.0 ft. [7.3 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:28.5 ft. [8.7 m]
Deck width edge-to-edge:30.8 ft. [9.4 m]
Skew angle:17°
Owner:County Highway Agency [02]
Year built:1940
Year reconstructed:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 13.5 / HS 15 [3]
Main span material:Prestressed concrete [5]
Main span design:Slab [01]
Deck type:Wood or Timber [8]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:415 [as of 2010]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:79.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairGoodGoodFair41579.6
October 2016FairGoodGoodSatisfactory41590.7
October 2014FairVery GoodVery GoodSatisfactory41590.6
September 2012GoodVery GoodVery GoodGood41590.6
November 2010FairVery GoodVery GoodFair41581.6
November 2008FairGoodFairFair41578.6
June 2006FairGoodFairFair39979.6
September 2004PoorGoodPoorFair39963.2
October 2002PoorVery GoodPoorFair38763.2
February 2001FairVery GoodFairSatisfactory37979.4
June 1998FairGoodSatisfactoryGood37990.4
April 1996FairGoodSatisfactoryGood71073.8
August 1994FairGoodSatisfactoryGood71073.8
September 1992FairGoodSatisfactoryFair66070.9
October 1990FairVery GoodSatisfactoryVery Good66080.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Deck
Prestressed Concrete Decksq. ft.80072050300
Wearing Surfacessq. ft.800800000
Substructure
Reinforced Concrete Abutmentlinear ft.931929450
Reinforced Concrete Pile Cap/Footinglinear ft.4804800
Joints
Other Jointlinear ft.6262000
Bearings
Elastomeric Bearingeach3232000
Bridge Rail