STATE STREET over MILL CREEK
Map
Coordinates:
+44.93122, -123.0071644°55'52" N, 123°00'26" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | STATE STREET over MILL CREEK |
Structure number: | 470249 |
Location: | W OF ARPT RD/DEP FORESTRY |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 40.0 ft. [12.2 m] |
Total length: | 107.0 ft. [32.6 m] |
Roadway width between curbs: | 71.9 ft. [21.9 m] |
Deck width edge-to-edge: | 86.0 ft. [26.2 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1929 |
Year reconstructed: | 1996 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 39,378 [as of 2010] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 66.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Satisfactory | Satisfactory | Fair | 39378 | 66.2 |
August 2015 | Fair | Satisfactory | Satisfactory | Fair | 39378 | 66.2 |
August 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 39378 | 77.2 |
September 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 39378 | 77.2 |
September 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 39378 | 78.3 |
October 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 38988 | 78.4 |
August 2005 | Fair | Satisfactory | Satisfactory | Good | 37852 | 81.6 |
July 2003 | Fair | Satisfactory | Satisfactory | Good | 37852 | 81.2 |
July 2001 | Fair | Satisfactory | Satisfactory | Good | 36750 | 81.4 |
July 1999 | Fair | Satisfactory | Satisfactory | Good | 35000 | 81.7 |
July 1997 | Fair | Satisfactory | Satisfactory | Good | 35000 | 81.7 |
June 1995 | Fair | Satisfactory | Satisfactory | Good | 15870 | 52.0 |
July 1993 | Good | Good | Good | Good | 15870 | 59.7 |
July 1991 | Fair | Satisfactory | Very Good | Good | 15870 | 59.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,280 | 0 | 1,274 | 6 | 0 |
Reinforced Concrete Floor Beam | linear ft. | 25 | 10 | 15 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 9,100 | 8,657 | 383 | 60 | 0 |
Wearing Surfaces | sq. ft. | 7,704 | 0 | 7,704 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 20 | 14 | 6 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 172 | 172 | 0 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 4 | 0 | 4 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 515 | 490 | 25 | 0 | 0 |
Joints |
Other Joint | linear ft. | 172 | 86 | 0 | 86 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 230 | 0 | 85 | 135 | 10 |