Share:

WILLAMETTE BLVD over BURLINGTON NORTHERN R&R

Map

Coordinates:
+45.58216, -122.74084
45°34'56" N, 122°44'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WILLAMETTE BLVD over BURLINGTON NORTHERN R&R
Structure number:51T102000000000
Location:N. WILLAMETTE OVER BURLIN
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Collector (Urban) [17]
Length of largest span:90.9 ft. [27.7 m]
Total length:339.9 ft. [103.6 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Vertical clearance below bridge:68.9 ft. [21.0 m]
Owner:Railroad [27]
Year built:1909
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Truss - Deck [09]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:10,361 [as of 2010]
Truck traffic:10% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:58.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,916,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2018PoorPoorPoorFair1036158.4
July 2016PoorPoorPoorFair1036158.4
July 2014PoorPoorPoorFair1036158.4
July 2012PoorPoorPoorFair1036158.4
November 2010PoorPoorPoorFair1036158.4
December 2009PoorPoorPoorSerious1036142.0
December 2008PoorPoorPoorSerious1036147.2
August 2007PoorPoorPoorSerious1025847.3
September 2006PoorPoorPoorSerious995947.4
August 2005PoorPoorPoorSerious995947.4
September 2004PoorPoorFairSerious995947.2
August 2002PoorPoorFairSerious995947.2
May 2000PoorFairFairPoor966564.4
July 1998PoorFairFairPoor966564.4
June 1996PoorPoorFairPoor966562.4
July 1994PoorPoorFairSerious966531.4
June 1992PoorPoorFairSerious929034.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.144479070
Steel Protective Coatingsq. ft.2,88001,800936144
Steel Stringerlinear ft.7,1403,9602,5126680
Steel Protective Coatingsq. ft.16,32040013,3601,744816
Deck
Reinforced Concrete Decksq. ft.20,400010,40010,0000
Wearing Surfacessq. ft.13,60013,600000
Superstructure
Steel Trusslinear ft.81004054050
Steel Protective Coatingsq. ft.7,44107444,4652,232
Steel Floor Beamlinear ft.1,9801,2006001800
Steel Protective Coatingsq. ft.10,8005,3202,7002,70080
Steel Gusset Plateeach117087300
Steel Protective Coatingsq. ft.1,872003121,560
Substructure
Steel Columneach1200120
Steel Protective Coatingsq. ft.4,500002,2502,250
Reinforced Concrete Abutmentlinear ft.1661511500
Reinforced Concrete Pile Cap/Footinglinear ft.1920178140
Joints
Other Jointlinear ft.2402281200
Bearings
Movable Bearingeach90360
Steel Protective Coatingsq. ft.81004833
Fixed Bearingeach90540
Steel Protective Coatingsq. ft.91444430
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,42076228450180
Steel Protective Coatingsq. ft.11,1652,289712,2026,603