ROUTE 60 over WEST END
Map
Coordinates:
+40.44400, -80.0296240°26'38" N, 80°01'47" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.
Facts
Name: | ROUTE 60 over WEST END |
Structure number: | 000000000045188 |
Old structure number: | 020060000400000 (from 1992 edition) |
Location: | BTWN MAIN AND STEUBEN STS |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 95.1 ft. [29.0 m] |
Total length: | 98.1 ft. [29.9 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 37.1 ft. [11.3 m] |
Skew angle: | 40° |
Owner: | State Highway Agency [01] |
Year built: | 2008 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: January 2015
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 30,565 [as of 2015] |
Truck traffic: | 3% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Operating rating: | 92.8 tons [84.4 metric tons] |
Inventory rating: | 46.9 tons [42.6 metric tons] |
Sufficiency rating: | 81.0 |
Recommended work: | Other structural work, including hydraulic replacements. [38] |
Previous Inspections
Date | Suff. Rating | Condition | Deck | Superstructure | Substructure | SD/FO | ADT |
---|
January 2015 | 81.0 | Good | Good | Very Good | Very Good | - | 30565 |
January 2013 | 81.0 | Good | Very Good | Very Good | Very Good | - | 30902 |
January 2011 | 81.0 | Good | Very Good | Very Good | Very Good | - | 8706 |
January 2009 | 81.0 | Good | Excellent | Excellent | Excellent | - | 8580 |