Share:

CROSS ST over SAW MILL RUN

Map

Coordinates:
+40.44500, -80.03000
40°26'42" N, 80°01'48" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:CROSS ST over SAW MILL RUN
Structure number:000000000000763
Old structure number:020060000401000 (from 1992 edition)
Location:WEST END CIRCLE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:35.1 ft. [10.7 m]
Total length:35.1 ft. [10.7 m]
Roadway width between curbs:48.6 ft. [14.8 m]
Deck width edge-to-edge:48.6 ft. [14.8 m]
Owner:State Highway Agency [01]
Year built:1929
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: July 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,710 [as of 2015]
Truck traffic:8% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:53.9 tons [49.0 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:86.5

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
July 201586.5Fair5 out of 10-9710
July 201386.5Fair5 out of 10-9817
July 201186.3FairN out of 10-12842
July 200986.5FairN out of 10-8580
July 200786.5FairN out of 10-8580
July 200585.5FairN out of 10-14239
October 200385.5FairN out of 10-13958
October 200184.5FairN out of 10-13467
October 199987.5Fair5 out of 10-13467
October 199788.4Fair5 out of 10-5917
October 199588.4Fair5 out of 10-7007
September 199388.4FairN out of 10-6788
September 199188.5FairN out of 10-6365