Share:

PARKWAY EAST(I376) over CSX RR,SWINEBURN,FRAZIER

Map 

Coordinates:
+40.42770, -79.95020
40°25'40" N, 79°57'01" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:PARKWAY EAST(I376) over CSX RR,SWINEBURN,FRAZIER
Structure number:000000000001157
Old structure number:020376003400000 (from 1992 edition)
Location:@ INT W/ FRAZIER STREET
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:264.1 ft. [80.5 m]
Total length:1015.1 ft. [309.4 m]
Roadway width between curbs:91.9 ft. [28.0 m]
Deck width edge-to-edge:95.5 ft. [29.1 m]
Vertical clearance below bridge:13.8 ft. [4.2 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1951
Year reconstructed:1981
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Truss - Deck [09]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: August 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:52,334 [as of 2015]
Truck traffic:8% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:42.9 tons [39.0 metric tons]
Inventory rating:24.0 tons [21.8 metric tons]
Sufficiency rating:52.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$3,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201552.8FairFairFairFairFO52334
August 201352.6FairFairFairFairFO55187
September 201162.8FairFairSatisfactorySatisfactoryFO31284
September 200962.8FairFairSatisfactorySatisfactoryFO45808
September 200763.8FairGoodSatisfactorySatisfactoryFO130303
September 200563.5FairSatisfactorySatisfactorySatisfactoryFO119131
September 200363.5FairSatisfactorySatisfactorySatisfactoryFO112876
September 200163.5FairSatisfactorySatisfactorySatisfactoryFO120888
September 199963.5FairSatisfactorySatisfactorySatisfactoryFO120286
September 199763.5FairSatisfactorySatisfactorySatisfactoryFO112464
October 199576.0FairSatisfactoryGoodSatisfactoryFO92878
October 199364.0FairFairSatisfactoryFairFO90612