Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PARKWAY EAST over HAYMAKER ROAD
Structure number:000000000001212
Old structure number:020376014015460 (from 1992 edition)
Location:I 376 E.B.OVER SR 2057
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:112.9 ft. [34.4 m]
Total length:116.1 ft. [35.4 m]
Roadway width between curbs:59.4 ft. [18.1 m]
Deck width edge-to-edge:63.0 ft. [19.2 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:43°
Owner:State Highway Agency [01]
Year built:1962
Year reconstructed:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:44,298 [as of 2017]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:92.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$461,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017FairGoodSatisfactoryGood4429892.0
January 2015FairSatisfactoryFairGood4624281.0
January 2013FairSatisfactoryFairGood4375081.0
January 2011FairSatisfactoryFairGood2711781.0
January 2009PoorFairFairPoor2684164.0
January 2007PoorFairFairPoor3304863.0
January 2005PoorFairFairPoor3240363.0
January 2003PoorFairFairPoor3325063.0
January 2001PoorFairFairPoor3215061.0
January 1999FairSatisfactorySatisfactoryFair3457681.0
January 1997FairSatisfactorySatisfactoryFair3248681.0
January 1995FairSatisfactorySatisfactoryFair3154081.0
January 1993FairSatisfactorySatisfactorySatisfactory3070992.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,1001,100000
Steel Protective Coatingsq. ft.10,75310,753000
Deck
Reinforced Concrete Decksq. ft.7,2147,1427200
Wearing Surfacessq. ft.6,8136,7456800
Substructure
Reinforced Concrete Abutmentlinear ft.203203000
Joints
Strip Seal Jointlinear ft.172172000
Bearings
Movable Bearingeach1010000
Steel Protective Coatingsq. ft.10,75310,753000
Fixed Bearingeach1010000
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.229229000