Share:

WETZEL RD over LITTLE PINE CREEK

Map

Coordinates:
+40.52278, -79.97055
40°31'22" N, 79°58'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WETZEL RD over LITTLE PINE CREEK
Structure number:000000000001951
Old structure number:024017006003970 (from 1992 edition)
Location:250'W.OF SR 4006
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:30.8 ft. [9.4 m]
Total length:30.8 ft. [9.4 m]
Roadway width between curbs:18.4 ft. [5.6 m]
Deck width edge-to-edge:23.3 ft. [7.1 m]
Skew angle:23°
Owner:State Highway Agency [01]
Year built:1936
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Arch - Deck [11]
Deck type:Not applicable [N]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:4,044 [as of 2016]
Truck traffic:7% of total traffic
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:47.5
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$253,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2016Poor-SatisfactoryPoor404447.5
August 2014Poor-SatisfactoryPoor409147.4
August 2012Poor-SatisfactoryPoor487049.9
August 2010Poor-SatisfactoryPoor492331.9
August 2009Poor-SeriousPoor49236.0
February 2009Poor-SeriousPoor49236.0
February 2008Poor-SeriousCritical46716.0
February 2007Poor-SeriousFair459730.8
February 2006Poor-SeriousFair455128.3
February 2004Poor-SeriousFair449728.3
February 2002Poor-SeriousFair387629.1
February 2000Poor-SeriousFair380729.2
February 1998Poor-SeriousFair605026.4
February 1996Poor-PoorFair579846.9
February 1994Poor-PoorFair561747.0
February 1992Poor-PoorFair561749.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Archlinear ft.3131000
Bridge Rail
Other Material Bridge Raillinear ft.6262000