Share:

OHIO RIVER BL over SR 0051;N&SRR;CSX;OHIO R

Map

Coordinates:
+40.53315, -80.18773
40°31'59" N, 80°11'16" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:OHIO RIVER BL over SR 0051;N&SRR;CSX;OHIO R
Structure number:000000000001966
Old structure number:024025001000970 (from 1992 edition)
Location:SEWICKLEY BRIDGE
Purpose:Carries highway and pedestrian walkway over highway, waterway, and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:750.0 ft. [228.6 m]
Total length:1852.1 ft. [564.5 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:44.3 ft. [13.5 m]
Vertical clearance above deck:19.7 ft. [6.0 m]
Vertical clearance below bridge:2647.8 ft. [807.0 m]
Owner:State Highway Agency [01]
Year built:1981
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:17,567 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:65.7
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$3,671,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairSatisfactorySatisfactorySatisfactory1756765.7
May 2015FairSatisfactorySatisfactoryFair1797157.2
May 2013FairSatisfactorySatisfactorySatisfactory1816971.5
May 2011FairSatisfactorySatisfactorySatisfactory1875171.0
May 2009FairSatisfactorySatisfactorySatisfactory1895470.9
May 2007FairSatisfactorySatisfactorySatisfactory2163669.1
October 2005Fair--Satisfactory1756765.0
May 2005FairSatisfactorySatisfactorySatisfactory2108169.2
May 2003FairSatisfactorySatisfactoryFair2083157.9
May 2001FairGoodSatisfactorySatisfactory2450273.0
June 1999GoodGoodGoodGood2450272.0
July 1997GoodGoodVery GoodGood2318072.0
August 1995GoodGoodVery GoodGood2230872.2
July 1993GoodGoodVery GoodGood2161168.0
August 1991GoodGoodGoodGood2366468.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,4572,457000
Steel Protective Coatingsq. ft.43,01343,013000
Steel Stringerlinear ft.8,8807,99288800
Steel Protective Coatingsq. ft.32,25932,259000
Deck
Reinforced Concrete Decksq. ft.68,564068,56400
Superstructure
Steel Trusslinear ft.3,0002,9901000
Steel Protective Coatingsq. ft.32,25932,259000
Steel Floor Beamlinear ft.1,7141,714000
Steel Protective Coatingsq. ft.53,76653,766000
Substructure
Reinforced Concrete Columneach88000
Masonry Pier Walllinear ft.100100000
Reinforced Concrete Abutmentlinear ft.1035136160
Reinforced Concrete Pier Caplinear ft.1811245700
Joints
Strip Seal Jointlinear ft.3600036
Compression Jointlinear ft.44836044044
Assembly without Seal Jointlinear ft.3636000
Bearings
Movable Bearingeach3434000
Steel Protective Coatingsq. ft.75,27275,272000
Fixed Bearingeach1616000
Steel Protective Coatingsq. ft.32,25932,259000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2,9482,948000