Facts 

Name:SOUTH NEGLEY AV over N-S RR & PAT EBUSWAY
Structure number:000000000002453
Old structure number:027301000031020 (from 1992 edition)
Location:301102 BTCENTRE&ELLSWORTH
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:104.0 ft. [31.7 m]
Total length:106.0 ft. [32.3 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:49.9 ft. [15.2 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Skew angle:17°
Owner:City or Municipal Highway Agency [04]
Year built:1924
Year reconstructed:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2015 

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:15,000 [as of 2005]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Operating rating:63.9 tons [58.1 metric tons]
Inventory rating:38.0 tons [34.5 metric tons]
Sufficiency rating:44.9
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$335,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201544.9PoorFairFairPoorSD15000
November 201342.6PoorFairFairPoorSD15000
November 201142.6PoorFairFairPoorSD15000
November 200942.6PoorFairFairPoorSD15000
November 200744.9PoorSatisfactoryFairPoorSD15000
November 200544.9PoorSatisfactoryFairPoorSD15000
November 200344.9PoorSatisfactoryFairPoorSD15000
November 200144.9PoorSatisfactoryFairPoorSD15000
November 199944.9PoorSatisfactoryFairPoorSD15000
November 199744.9PoorSatisfactorySatisfactoryPoorSD15000
August 199644.9PoorSatisfactorySatisfactoryPoorSD15000
November 199547.1PoorGoodSatisfactoryPoorSD15000
November 199347.1PoorGoodSatisfactoryPoorSD15000
November 199147.1PoorGoodSatisfactoryPoorSD15000