Share:

TIMBERLAND AV over SAW MILL RUN CREEK

Map 

Coordinates:
+40.41079, -80.00591
40°24'39" N, 80°00'21" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:TIMBERLAND AV over SAW MILL RUN CREEK
Structure number:000000000002459
Old structure number:027301000031130 (from 1992 edition)
Location:301113 OFF RT 51 S
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:28.9 ft. [8.8 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:12.1 ft. [3.7 m]
Deck width edge-to-edge:14.1 ft. [4.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1909
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Main span material:Concrete [1]
Main span design:Other [00]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2015 

Good/Fair/Poor Condition:Poor
Status:Bridge closed to all traffic [K]
Average daily traffic:30 [as of 2010]
Truck traffic:1% of total traffic
Deck condition:Imminent Failure [1 out of 9]
Superstructure condition:Imminent Failure [1 out of 9]
Substructure condition:Serious [3 out of 9]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:8.0 tons [7.3 metric tons]
Inventory rating:5.0 tons [4.5 metric tons]
Sufficiency rating:16.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$107,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201516.8PoorImminent FailureImminent FailureSeriousSD30
October 201316.8PoorSeriousPoorSeriousSD30
October 201116.8PoorSeriousPoorPoorSD30
October 201016.8PoorSeriousPoorFairSD30
October 200916.8PoorSeriousFairFairSD30
October 200816.8PoorSeriousFairFairSD30
October 200716.8PoorSeriousFairFairSD30
September 200616.8PoorSeriousFairFairSD30
October 200516.8PoorSeriousFairFairSD30
October 200416.8PoorSeriousFairFairSD30
November 200316.8PoorPoorFairFairSD30
November 200216.8PoorPoorFairFairSD30
November 200116.8PoorPoorFairFairSD30
November 200019.4PoorPoorFairFairSD30
December 199919.4PoorPoorFairFairSD30
October 199816.8PoorPoorFairFairSD30
February 199716.8PoorPoorFairPoorSD30
September 199617.9PoorFairFairPoorSD30
January 199518.9PoorSatisfactorySatisfactoryPoorSD30
January 199418.9PoorSatisfactorySatisfactoryPoorSD30
January 199318.9PoorSatisfactorySatisfactoryPoorSD30
January 199218.9PoorSatisfactorySatisfactoryPoorSD30