Share:

RAMP C over RAMP D UNDERPASS EB.

Map

Coordinates:
+40.44167, -80.00833
40°26'30" N, 80°00'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP C over RAMP D UNDERPASS EB.
Structure number:000000000002908
Old structure number:028095002002250 (from 1992 edition)
Location:AT INT W/ GRANT STREET
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:29.9 ft. [9.1 m]
Total length:34.1 ft. [10.4 m]
Roadway width between curbs:44.9 ft. [13.7 m]
Deck width edge-to-edge:163.1 ft. [49.7 m]
Vertical clearance above deck:14.8 ft. [4.5 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:12,276 [as of 2014]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Operating rating:53.9 tons [49.0 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:76.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201576.0FairSatisfactorySatisfactorySatisfactoryFO12276
October 201376.0FairSatisfactorySatisfactoryGoodFO12276
October 201176.0FairGoodSatisfactoryGoodFO6713
October 200976.0FairGoodSatisfactoryGoodFO6759
October 200776.0FairExcellentSatisfactoryGoodFO6759
October 200576.0FairExcellentSatisfactoryGoodFO6585
October 200376.0FairExcellentSatisfactoryGoodFO6455
October 200178.0FairSatisfactorySatisfactoryGoodFO6229
October 199977.0FairSatisfactorySatisfactoryGoodFO6119
October 199777.0FairSatisfactorySatisfactoryGoodFO7542
October 199577.0FairSatisfactorySatisfactoryGoodFO7409

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Reinforced Concrete Abutmentlinear ft.336336000
Bridge Rail
Other Material Bridge Raillinear ft.136136000
Deck
Reinforced Concrete Slabsq. ft.5,5425,4875500