Share:

RAMP A over I-376 WB UNDERPASS

Map

Coordinates:
+40.43454, -79.98873
40°26'04" N, 79°59'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP A over I-376 WB UNDERPASS
Structure number:000000000002912
Old structure number:028095050004870 (from 1992 edition)
Location:AT INT W/ GRANT STREET
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:34.1 ft. [10.4 m]
Total length:38.1 ft. [11.6 m]
Roadway width between curbs:75.1 ft. [22.9 m]
Deck width edge-to-edge:259.9 ft. [79.2 m]
Vertical clearance above deck:14.1 ft. [4.3 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Owner:State Highway Agency [01]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:28,015 [as of 2014]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Operating rating:53.9 tons [49.0 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:87.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201587.0FairSatisfactorySatisfactorySatisfactoryFO28015
October 201387.0FairSatisfactorySatisfactorySatisfactoryFO28015
October 201176.0FairGoodSatisfactoryFairFO7119
October 200978.0FairGoodSatisfactoryFairFO7168
October 200789.0GoodGoodGoodGoodFO7168
October 200589.0GoodGoodGoodGoodFO250
October 200389.0GoodGoodGoodGoodFO246
October 200194.0GoodGoodGoodGoodFO238
October 199996.0GoodGoodGoodGoodFO234
October 199790.0GoodGoodGoodGoodFO226
October 199592.0GoodGoodGoodGoodFO1000
September 199392.0GoodGoodGoodGoodFO1000
September 199196.0GoodGoodGoodGood-1000

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Reinforced Concrete Abutmentlinear ft.526526000
Bridge Rail
Other Material Bridge Raillinear ft.228228000
Deck
Reinforced Concrete Slabsq. ft.9,8809,28759300
Wearing Surfacessq. ft.2,7362,736000