Share:

I-376 O/ BRADYS RN over SR 4012, BRADYS RUN PK.

Map

Coordinates:
+40.72211, -80.36881
40°43'20" N, 80°22'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-376 O/ BRADYS RN over SR 4012, BRADYS RUN PK.
Structure number:000000000003534
Old structure number:040060024100000 (from 1992 edition)
Location:I-376 O/ BRADYS RUN PARK
Purpose:Carries highway over highway and waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:244.1 ft. [74.4 m]
Total length:1360.0 ft. [414.5 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:44.3 ft. [13.5 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1971
Year reconstructed:2011
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Steel continuous [4]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,630 [as of 2018]
Truck traffic:12% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:80.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$7,346,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairSatisfactoryFairSatisfactory1063080.1
May 2016FairSatisfactoryFairSatisfactory1080377.8
May 2014FairSatisfactoryFairFair1017078.5
May 2012FairSatisfactoryFairFair994178.4
May 2010FairSatisfactoryFairFair1100478.4
May 2009FairSatisfactoryFairFair1100480.4
June 2007FairSatisfactoryFairFair1142980.4
June 2006FairSatisfactoryFairFair1128680.4
July 2005FairSatisfactoryFairFair1127379.5
July 2004FairSatisfactoryFairFair1127379.5
July 2003FairSatisfactoryFairFair1103579.6
July 2002FairSatisfactoryFairFair1039879.6
May 2001FairSatisfactoryFairFair1101679.6
May 2000FairSatisfactoryFairFair1101679.6
July 1999FairSatisfactoryFairFair1101677.6
August 1998FairSatisfactoryFairFair928077.8
June 1997FairSatisfactoryFairFair911677.8
August 1996FairSatisfactoryFairFair911677.8
July 1995FairSatisfactorySatisfactoryFair914181.2
October 1994FairSatisfactorySatisfactoryFair899781.2
April 1993FairSatisfactoryFairFair899781.2
May 1992PoorFairPoorFair747166.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,6932,693000
Steel Protective Coatingsq. ft.75,27275,272000
Steel Stringerlinear ft.5,3825,382000
Steel Protective Coatingsq. ft.75,27275,272000
Deck
Reinforced Concrete Decksq. ft.58,36957,83653300
Wearing Surfacessq. ft.53,82653,33549100
Superstructure
Steel Floor Beamlinear ft.2,4732,473000
Steel Protective Coatingsq. ft.75,27275,272000
Substructure
Reinforced Concrete Pier Walllinear ft.72048240
Reinforced Concrete Abutmentlinear ft.1162670200
Reinforced Concrete Pier Caplinear ft.2600217430
Joints
Strip Seal Jointlinear ft.8686000
Compression Jointlinear ft.4343000
Other Jointlinear ft.8686000
Bearings
Movable Bearingeach1212000
Steel Protective Coatingsq. ft.64,51964,519000
Fixed Bearingeach88000
Steel Protective Coatingsq. ft.43,01343,013000
Bridge Rail
Other Material Bridge Raillinear ft.2,6932,6761700