PA 61 (LR 160) over I-78 (LR 285)
Map
Coordinates:
+40.55704, -75.9980840°33'25" N, 75°59'53" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | PA 61 (LR 160) over I-78 (LR 285) |
Structure number: | 000000000004607 |
Old structure number: | 060061037400000 (from 1992 edition) |
Location: | I-78/PA 61 INTERCHANGE |
Purpose: | Carries highway overpass over highway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 78.1 ft. [23.8 m] |
Total length: | 160.1 ft. [48.8 m] |
Roadway width between curbs: | 67.9 ft. [20.7 m] |
Deck width edge-to-edge: | 71.9 ft. [21.9 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 15° |
Owner: | State Highway Agency [01] |
Year built: | 1954 |
Year reconstructed: | 1992 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: June 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 21,979 [as of 2018] |
Truck traffic: | 16% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 75.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $421,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2018 | Fair | Fair | Satisfactory | Fair | 21979 | 75.4 |
June 2016 | Fair | Good | Satisfactory | Fair | 23100 | 77.6 |
June 2014 | Fair | Good | Satisfactory | Fair | 22220 | 80.7 |
June 2012 | Fair | Good | Satisfactory | Fair | 11109 | 81.4 |
June 2010 | Fair | Good | Satisfactory | Fair | 10420 | 81.4 |
July 2008 | Fair | Good | Satisfactory | Fair | 10420 | 81.4 |
July 2006 | Fair | Good | Good | Satisfactory | 20956 | 88.9 |
July 2004 | Fair | Good | Good | Satisfactory | 19794 | 87.9 |
August 2002 | Fair | Good | Good | Satisfactory | 20130 | 85.9 |
September 2000 | Fair | Good | Good | Satisfactory | 19930 | 85.9 |
September 1998 | Fair | Good | Good | Satisfactory | 19764 | 86.9 |
October 1996 | Fair | Good | Good | Satisfactory | 18624 | 87.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 2,206 | 1,706 | 500 | 0 | 0 |
Steel Protective Coating | sq. ft. | 16,956 | 0 | 16,956 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 11,346 | 11,186 | 160 | 0 | 0 |
Wearing Surfaces | sq. ft. | 10,716 | 10,513 | 148 | 55 | 0 |
Substructure |
Reinforced Concrete Column | each | 12 | 8 | 4 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 141 | 90 | 45 | 6 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 146 | 136 | 8 | 2 | 0 |
Joints |
Strip Seal Joint | linear ft. | 154 | 0 | 154 | 0 | 0 |
Pourable Joint | linear ft. | 154 | 130 | 12 | 0 | 12 |
Bearings |
Movable Bearing | each | 42 | 17 | 25 | 0 | 0 |
Steel Protective Coating | sq. ft. | 150 | 100 | 50 | 0 | 0 |
Fixed Bearing | each | 14 | 14 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 50 | 0 | 50 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 315 | 275 | 40 | 0 | 0 |