ON TSR 680 over MOSHANNON CREEK
Map
Coordinates:
+40.89470, -78.2241840°53'41" N, 78°13'27" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ON TSR 680 over MOSHANNON CREEK |
Structure number: | 000000000011715 |
Old structure number: | 172020001000000 (from 1992 edition) |
Location: | CHESTER HILL BORO |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 123.0 ft. [37.5 m] |
Total length: | 128.0 ft. [39.0 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 26.2 ft. [8.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1940 |
Year reconstructed: | 1971 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Closed Grating [4] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,092 [as of 2017] |
Truck traffic: | 4% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 54.6 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $1,407,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Fair | Fair | Satisfactory | 2092 | 54.6 |
March 2015 | Fair | Fair | Fair | Satisfactory | 2102 | 54.8 |
March 2013 | Fair | Fair | Fair | Satisfactory | 2251 | 54.8 |
November 2011 | Fair | Fair | Fair | Satisfactory | 2324 | 54.8 |
March 2011 | Fair | Fair | Fair | Satisfactory | 2349 | 54.8 |
March 2009 | Fair | Fair | Fair | Satisfactory | 2922 | 54.7 |
March 2007 | Fair | Fair | Fair | Satisfactory | 2875 | 54.7 |
March 2006 | Fair | Fair | Fair | Satisfactory | 2875 | 60.6 |
March 2005 | Fair | Fair | Fair | Satisfactory | 2630 | 60.6 |
March 2004 | Fair | Fair | Fair | Satisfactory | 2591 | 60.6 |
March 2003 | Fair | Fair | Fair | Satisfactory | 2548 | 60.6 |
March 2002 | Fair | Fair | Fair | Satisfactory | 2522 | 60.6 |
March 2001 | Fair | Fair | Fair | Satisfactory | 2522 | 60.6 |
March 2000 | Fair | Fair | Fair | Satisfactory | 1275 | 62.8 |
March 1998 | Fair | Fair | Fair | Satisfactory | 1224 | 62.8 |
March 1995 | Fair | Fair | Fair | Satisfactory | 1176 | 62.9 |
June 1994 | Fair | Fair | Satisfactory | Satisfactory | 1160 | 73.9 |
April 1993 | Fair | Fair | Satisfactory | Satisfactory | 1144 | 73.9 |
March 1992 | Fair | Fair | Satisfactory | Satisfactory | 1144 | 73.9 |
July 1991 | Fair | Fair | Satisfactory | Satisfactory | 1111 | 73.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 768 | 768 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Steel Truss | linear ft. | 256 | 246 | 10 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 245 | 245 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 79 | 69 | 5 | 5 | 0 |
Deck |
Concrete Filled Grid Deck | sq. ft. | 3,072 | 3,072 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 3,072 | 3,072 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Fixed Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |