Share:

SR 2012 over BALD EAGLE CR/CR.RD/CARO

Map

Coordinates:
+41.12487, -77.43533
41°07'30" N, 77°26'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 2012 over BALD EAGLE CR/CR.RD/CARO
Structure number:000000000012331
Old structure number:182012002404400 (from 1992 edition)
Location:CASTANEA FIREMENS MEMORIA
Purpose:Carries highway and pedestrian walkway over highway and waterway
Route classification:Collector (Urban) [17]
Length of largest span:120.1 ft. [36.6 m]
Total length:485.9 ft. [148.1 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:53.5 ft. [16.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:4
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:932 [as of 2017]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:99.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017GoodGoodGoodGood93299.2
April 2015GoodGoodGoodGood93499.2
April 2013GoodGoodGoodGood93499.2
April 2011GoodGoodGoodGood150198.7
April 2009GoodGoodGoodVery Good151198.7
April 2007GoodVery GoodGoodVery Good377896.8
May 2005GoodVery GoodGoodVery Good370696.9
June 2003GoodVery GoodGoodVery Good366996.9
June 2001GoodVery GoodGoodVery Good39099.7
November 2000GoodVery GoodGoodVery Good39099.7
June 1999GoodVery GoodGoodVery Good38299.7
July 1997GoodVery GoodVery GoodVery Good496195.8
August 1996GoodExcellentVery GoodVery Good496195.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2,3622,362000
Deck
Reinforced Concrete Decksq. ft.25,96125,961000
Substructure
Reinforced Concrete Pier Walllinear ft.8484000
Reinforced Concrete Abutmentlinear ft.122122000
Reinforced Concrete Pier Caplinear ft.156156000
Joints
Strip Seal Jointlinear ft.110110000
Bearings
Elastomeric Bearingeach3030000
Pot Bearingeach1010000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.9708749600