Share:

PA 75; SR 0075 over BUCK RUN

Map

Coordinates:
+39.86619, -77.89544
39°51'58" N, 77°53'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PA 75; SR 0075 over BUCK RUN
Structure number:000000000017339
Old structure number:280075021014650 (from 1992 edition)
Location:DICKEY STATION
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:42.0 ft. [12.8 m]
Total length:44.9 ft. [13.7 m]
Roadway width between curbs:31.5 ft. [9.6 m]
Deck width edge-to-edge:33.5 ft. [10.2 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Other [9]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:1,776 [as of 2017]
Truck traffic:11% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:61.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$134,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017PoorPoorPoorSatisfactory177661.1
December 2015PoorPoorPoorSatisfactory177961.1
December 2013FairFairFairSatisfactory179379.3
December 2011FairFairFairSatisfactory174279.3
January 2010FairFairFairSatisfactory209481.2
January 2008FairGoodSatisfactorySatisfactory205093.3
January 2006FairGoodSatisfactorySatisfactory196294.3
March 2004FairGoodSatisfactoryGood199094.3
March 2002FairGoodSatisfactoryGood194794.3
March 2000FairGoodSatisfactoryGood192794.3
January 1998FairGoodSatisfactoryGood176494.3
December 1995GoodGoodGoodGood289991.6
November 1993GoodGoodGoodGood277691.6
January 1992GoodGoodGoodGood266694.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.46236010200
Deck
Reinforced Concrete Decksq. ft.1,5081,508000
Wearing Surfacessq. ft.1,4181,418000
Substructure
Reinforced Concrete Abutmentlinear ft.10297500
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.9090000
Steel Protective Coatingsq. ft.10,75310,753000