FIFTH AVE over FALLING SPRING BRANCH
Map
Coordinates:
+39.93930, -77.6501039°56'21" N, 77°39'00" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FIFTH AVE over FALLING SPRING BRANCH |
Structure number: | 000000000017740 |
Old structure number: | 287401200540040 (from 1992 edition) |
Location: | 0.6 MI NE CHAMBERSBURG SQ |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 28.9 ft. [8.8 m] |
Total length: | 29.9 ft. [9.1 m] |
Roadway width between curbs: | 30.2 ft. [9.2 m] |
Deck width edge-to-edge: | 58.4 ft. [17.8 m] |
Skew angle: | 16° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1930 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Concrete [1] |
Main span design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: December 2017
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,000 [as of 2009] |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 46.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $340,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2017 | Poor | Poor | Poor | Fair | 6000 | 46.9 |
December 2015 | Poor | Poor | Poor | Fair | 6000 | 46.9 |
December 2013 | Poor | Poor | Poor | Fair | 6000 | 46.9 |
December 2011 | Poor | Poor | Poor | Fair | 6000 | 46.9 |
December 2009 | Poor | Poor | Poor | Fair | 6000 | 49.0 |
December 2007 | Fair | Fair | Fair | Fair | 6000 | 67.7 |
June 2006 | Fair | Fair | Fair | Fair | 6000 | 67.7 |
May 2004 | Fair | Fair | Fair | Fair | 6000 | 67.7 |
January 2002 | Fair | Fair | Fair | Fair | 6000 | 67.7 |
August 1999 | Fair | Fair | Fair | Fair | 6000 | 67.7 |