Share:

SR 75-PA 75 over FIRST ST & JUNIATA RIVER

Map

Coordinates:
+40.53367, -77.38457
40°32'01" N, 77°23'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 75-PA 75 over FIRST ST & JUNIATA RIVER
Structure number:000000000020038
Old structure number:340075068000000 (from 1992 edition)
Location:PORT ROYAL BORO
Purpose:Carries highway and pedestrian walkway over highway and waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:223.1 ft. [68.0 m]
Total length:1087.0 ft. [331.3 m]
Roadway width between curbs:23.0 ft. [7.0 m]
Deck width edge-to-edge:24.9 ft. [7.6 m]
Vertical clearance above deck:13.8 ft. [4.2 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Owner:State Highway Agency [01]
Year built:1937
Year reconstructed:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,775 [as of 2016]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:51.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,907,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2016FairGoodFairFair577551.1
March 2014FairGoodFairFair590948.7
May 2012FairGoodFairFair599546.4
March 2012FairGoodFairFair599546.4
March 2010PoorSatisfactorySeriousPoor483810.0
March 2008PoorSatisfactorySatisfactoryPoor482532.7
March 2006PoorSatisfactorySatisfactoryPoor515043.6
March 2005PoorSatisfactorySatisfactoryPoor505943.7
March 2003PoorSatisfactorySatisfactoryPoor498443.8
March 2002PoorSatisfactorySatisfactoryPoor560042.9
October 2000PoorSatisfactorySatisfactoryPoor783139.7
March 2000PoorSatisfactorySatisfactoryPoor767740.0
March 1999PoorSatisfactorySatisfactoryPoor767740.0
March 1997PoorSatisfactorySatisfactoryPoor696041.0
March 1995PoorSatisfactorySatisfactoryPoor671741.5
May 1993PoorSatisfactorySatisfactoryPoor661141.6
March 1993PoorSatisfactorySatisfactoryPoor661141.6
May 1991PoorSatisfactorySatisfactoryPoor383645.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.68950401850
Steel Protective Coatingsq. ft.32,25932,259000
Steel Stringerlinear ft.4,9514,951000
Steel Protective Coatingsq. ft.53,76653,766000
Deck
Reinforced Concrete Decksq. ft.21,76820,4621,30600
Wearing Surfacessq. ft.24,75323,2681,48500
Superstructure
Steel Trusslinear ft.1,7601,760000
Steel Protective Coatingsq. ft.43,01343,013000
Steel Floor Beamlinear ft.1,2691,269000
Steel Protective Coatingsq. ft.53,76653,766000
Substructure
Reinforced Concrete Columneach63300
Reinforced Concrete Pier Walllinear ft.1946213200
Reinforced Concrete Abutmentlinear ft.71284300
Reinforced Concrete Pier Caplinear ft.70581200
Joints
Strip Seal Jointlinear ft.100100000
Assembly without Seal Jointlinear ft.3939000
Other Jointlinear ft.9393000
Bearings
Movable Bearingeach2424000
Steel Protective Coatingsq. ft.75,27275,272000
Fixed Bearingeach2626000
Steel Protective Coatingsq. ft.86,02586,025000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2,1452,145000
Deck
Reinforced Concrete Slabsq. ft.5925563600
Wearing Surfacessq. ft.5925563600