Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 0084 I-84 EB over LACK CO RR & ROARING BR
Structure number:000000000020500
Old structure number:350084002004280 (from 1992 edition)
Location:ROARING BR TWP .3ME TR435
Purpose:Carries highway over railroad and waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:184.1 ft. [56.1 m]
Total length:1067.0 ft. [325.2 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Vertical clearance below bridge:75.5 ft. [23.0 m]
Owner:State Highway Agency [01]
Year built:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:20,829 [as of 2016]
Truck traffic:26% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:43.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$2,169,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016PoorPoorPoorPoor2082943.8
July 2015PoorPoorPoorFair2092943.8
February 2015PoorPoorPoorFair2215343.8
February 2013PoorPoorFairFair1946169.3
February 2011PoorPoorSatisfactorySatisfactory2013180.6
September 2009FairFairSatisfactorySatisfactory2071483.6
March 2009FairFairSatisfactorySatisfactory2325383.5
April 2007FairFairSatisfactorySatisfactory2271282.5
July 2005FairFairSatisfactorySatisfactory2038081.3
March 2005FairFairFairSatisfactory1972969.9
October 2003FairFairSatisfactorySatisfactory1915486.5
October 2002FairSatisfactorySatisfactorySatisfactory1859689.6
September 2001FairSatisfactorySatisfactorySatisfactory1815889.6
September 2000FairSatisfactorySatisfactorySatisfactory1815889.6
May 1999FairSatisfactorySatisfactorySatisfactory1559789.9
September 1998FairGoodGoodSatisfactory1521792.2
December 1997FairGoodGoodSatisfactory1484692.2
May 1996FairSatisfactoryGoodSatisfactory1448490.2
May 1995FairSatisfactoryGoodSatisfactory1399489.3
March 1994FairSatisfactoryGoodSatisfactory1365389.4
June 1993FairSatisfactoryGoodGood1332087.3
August 1991FairSatisfactoryGoodGood1255687.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,1202,120000
Steel Protective Coatingsq. ft.75,27275,272000
Steel Stringerlinear ft.5,3055,305000
Steel Protective Coatingsq. ft.75,27275,272000
Deck
Reinforced Concrete Decksq. ft.47,16847,168000
Superstructure
Steel Floor Beamlinear ft.2,1722,172000
Steel Protective Coatingsq. ft.75,27275,272000
Substructure
Reinforced Concrete Columneach1212000
Reinforced Concrete Abutmentlinear ft.198198000
Reinforced Concrete Pier Caplinear ft.221221000
Joints
Pourable Jointlinear ft.9090000
Compression Jointlinear ft.225225000
Bearings
Movable Bearingeach1010000
Steel Protective Coatingsq. ft.53,76653,766000
Fixed Bearingeach1414000
Steel Protective Coatingsq. ft.75,27275,272000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2,1442,144000